Schneider Electric LV846191

Schneider Electric LV846191 MasterPact MTZ2, 1000 A, 100 kA

MPN LV846191
Active

Schneider Electric MasterPacT series, MasterPact MTZ2 drawout circuit breaker, LV846191, 4P, 1000 A rated, 100 kA breaking capacity at 415 V AC.

$18,506.59 – $19,431.93 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846191 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846191 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 drawout breaker, 1000 A frame

The LV846191 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 4-pole, rated 1000 A continuous at 40 °C. That 100 kA at 415 V AC is the rated ultimate breaking capacity (Icu); the service breaking capacity (Ics) is also 100 kA at both 220/415 V and 440 V AC, meaning after clearing a fault at full rating the breaker can be reclosed and continue to carry load — full discrimination is maintained.

Rated short-time withstand current (Icw) is 100 kA for 0.5 s and 1 s, 75 kA for 3 s — this is the thermal and mechanical stress the breaker can handle during a delayed trip coordination scheme. Category B selectivity means it's designed for full selectivity with downstream devices, critical for a distribution panel where you want only the faulted branch to open. Rated insulation voltage (Ui) is 1000 V AC, impulse withstand (Uimp) is 12 kV — the clearances and creepage are sized for 1000 V class switchgear, so it fits into a 1000 V bus system even though the operational voltage is 440 V. Mechanical durability is 15,000 cycles with periodic preventive maintenance; electrical durability is 10,000 cycles at 440 V AC at rated current per EN/IEC 60947-2 AC-23A, and 6,000 cycles at 440 V AC per EN/IEC 60947-3 AC-3. Maximum breaking time is 25 ms, closing response time 70 ms — fast enough for most coordination schemes.

Drawout mounting means the breaker chassis stays wired to the bus; the moving portion pulls out for inspection or swap without disturbing the power connections. Mounting support is rails or base plate. Connection pitch is 115 mm. Upside and downside connections are available in both front and rear configurations — rear connection is typical for switchgear lineups where the breaker slides into a cassette; front connection suits standalone enclosures. Neutral position is left.

Operating altitude is 0–2000 m without derating, 2000–5000 m with derating.