Skip to main content
Schneider Electric LV846191 — Air Circuit Breakers

Schneider Electric LV846191 MasterPact MTZ2, 1000 A, 100 kA

MPNLV846191
Active

Schneider Electric MasterPacT series, MasterPact MTZ2 drawout circuit breaker, LV846191, 4P, 1000 A rated, 100 kA breaking capacity at 415 V AC.

$18,506.59 – $19,431.93Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV846191 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV846191 — Electrical ratings
ParameterValue
Rated current (In)1000 A at 40 °C
Sensor rating400 A 630 A 800 A 1000 A
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV846191 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 0.5 s 100 kA 1 s 75 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz
Performance typeH2V 100 kA 415 V AC
LV846191 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)15000 cycles with periodic preventive maintenance
Electrical durability (cycles)10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation150 W
LV846191 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
Width556 mm
Height439 mm
Depth403 mm
Neutral pole positionLeft
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV846191 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV846191 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

MasterPact MTZ2 drawout breaker, 1000 A frame

The LV846191 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 4-pole, rated 1000 A continuous at 40 °C. That 100 kA at 415 V AC is the rated ultimate breaking capacity (Icu); the service breaking capacity (Ics) is also 100 kA at both 220/415 V and 440 V AC, meaning after clearing a fault at full rating the breaker can be reclosed and continue to carry load — full discrimination is maintained.

Rated short-time withstand current (Icw) is 100 kA for 0.5 s and 1 s, 75 kA for 3 s — this is the thermal and mechanical stress the breaker can handle during a delayed trip coordination scheme. Category B selectivity means it's designed for full selectivity with downstream devices, critical for a distribution panel where you want only the faulted branch to open. Rated insulation voltage (Ui) is 1000 V AC, impulse withstand (Uimp) is 12 kV — the clearances and creepage are sized for 1000 V class switchgear, so it fits into a 1000 V bus system even though the operational voltage is 440 V. Mechanical durability is 15,000 cycles with periodic preventive maintenance; electrical durability is 10,000 cycles at 440 V AC at rated current per EN/IEC 60947-2 AC-23A, and 6,000 cycles at 440 V AC per EN/IEC 60947-3 AC-3. Maximum breaking time is 25 ms, closing response time 70 ms — fast enough for most coordination schemes.

Drawout mounting means the breaker chassis stays wired to the bus; the moving portion pulls out for inspection or swap without disturbing the power connections. Mounting support is rails or base plate. Connection pitch is 115 mm. Upside and downside connections are available in both front and rear configurations — rear connection is typical for switchgear lineups where the breaker slides into a cassette; front connection suits standalone enclosures. Neutral position is left.

Operating altitude is 0–2000 m without derating, 2000–5000 m with derating.

Frequently asked questions

How do I get current pricing and availability for LV846191?

The LV846191 is sourced to order against an RFQ through independent distribution; current pricing and availability are confirmed at quote time.

What is LV846191's rated current and breaking capacity?

Rated current is 1000 A at 40 °C; ultimate breaking capacity (Icu) is 100 kA at 415 V AC, and service breaking capacity (Ics) is also 100 kA at 220/415 V and 440 V AC.

What compliance documentation does this breaker meet?

Certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. Suitability for isolation is confirmed per EN/IEC 60947-2.

MPN