Schneider Electric LV846193

Schneider Electric LV846193 MasterPact MTZ2 1600A, 100kA, 4P

MPN LV846193
Active

Schneider Electric MasterPacT MTZ2, drawout circuit breaker, LV846193, 1600 A at 40 °C, H2V 100 kA at 415 V AC, 4 poles, 556 x 439 x 403 mm.

$6,954.66 – $19,431.93 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846193 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846193 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

What this MasterPact MTZ2 does on the line

The Schneider Electric LV846193 is a MasterPact MTZ2 drawout circuit breaker rated 1600 A at 40 °C, with a H2V performance class delivering 100 kA interrupting capacity at 415 V AC. Four poles, category B selectivity — meaning it coordinates with downstream breakers to isolate only the faulted branch, keeping the rest of the distribution live. This is the part you spec into a main or tie breaker position in a low-voltage switchboard where fault current runs high and uptime matters.

Rated 1600 A continuous at 40 °C — that's the full-frame current, not a derated summer number. If your switchgear ambient runs higher, you'll need to consult the thermal derating curve, but for a typical 40 °C panel this breaker carries its nameplate all day. Icw is 100 kA for 1 second, so it holds in through delayed-tripping coordination schemes. Rated insulation voltage 1000 V AC, impulse withstand 12 kV — this breaker is built for 690 V switchgear applications even though the operational voltage here is listed at 440 V AC. The 12 kV impulse rating means it survives lightning surges and switching transients on industrial networks.

Drawout mounting and panel integration

Drawout chassis — the breaker cassette slides into a fixed cradle, so you can rack it out for maintenance or replacement without disconnecting power cables. Mounts on rails or a base plate; connection pitch is 115 mm. Front and rear connection options on both upside and downside give flexibility for cable or busbar entry in a switchboard lineup. Dimensions: 556 mm wide, 439 mm high, 403 mm deep. That depth matters when you're laying out a cubicle — make sure the door clearance and rear cable space accommodate the drawout travel.

MPN
LV846193