Schneider Electric LV846193 — Air Circuit Breakers

Schneider Electric LV846193 MasterPact MTZ2 1600A, 100kA, 4P

MPNLV846193
Active

Schneider Electric MasterPacT MTZ2, drawout circuit breaker, LV846193, 1600 A at 40 °C, H2V 100 kA at 415 V AC, 4 poles, 556 x 439 x 403 mm.

$6,954.66 – $19,431.93Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LV846193 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV846193 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Sensor rating800 A 1000 A 1250 A 1600 A
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV846193 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz
Rated short-time withstand current (Icw)100 kA 0.5 s 100 kA 1 s 75 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz
Performance typeH2V 100 kA 415 V AC
LV846193 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)15000 cycles with periodic preventive maintenance
Electrical durability (cycles)10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation390 W
LV846193 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
Width556 mm
Height439 mm
Depth403 mm
Neutral pole positionLeft
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV846193 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV846193 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

What this MasterPact MTZ2 does on the line

The Schneider Electric LV846193 is a MasterPact MTZ2 drawout circuit breaker rated 1600 A at 40 °C, with a H2V performance class delivering 100 kA interrupting capacity at 415 V AC. Four poles, category B selectivity — meaning it coordinates with downstream breakers to isolate only the faulted branch, keeping the rest of the distribution live. This is the part you spec into a main or tie breaker position in a low-voltage switchboard where fault current runs high and uptime matters.

Rated 1600 A continuous at 40 °C — that's the full-frame current, not a derated summer number. If your switchgear ambient runs higher, you'll need to consult the thermal derating curve, but for a typical 40 °C panel this breaker carries its nameplate all day. Icw is 100 kA for 1 second, so it holds in through delayed-tripping coordination schemes. Rated insulation voltage 1000 V AC, impulse withstand 12 kV — this breaker is built for 690 V switchgear applications even though the operational voltage here is listed at 440 V AC. The 12 kV impulse rating means it survives lightning surges and switching transients on industrial networks.

Drawout mounting and panel integration

Drawout chassis — the breaker cassette slides into a fixed cradle, so you can rack it out for maintenance or replacement without disconnecting power cables. Mounts on rails or a base plate; connection pitch is 115 mm. Front and rear connection options on both upside and downside give flexibility for cable or busbar entry in a switchboard lineup. Dimensions: 556 mm wide, 439 mm high, 403 mm deep. That depth matters when you're laying out a cubicle — make sure the door clearance and rear cable space accommodate the drawout travel.

Frequently asked questions

What is the breaking capacity of LV846193?

H2V performance class: 100 kA at 415 V AC (Icu and Ics both 100 kA). Short-time withstand (Icw) is 100 kA for 1 second, 75 kA for 3 seconds.

Where can I buy LV846193 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What standards does LV846193 comply with?

EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. Suitable for isolation per EN/IEC 60947-2.