Skip to main content
Schneider Electric LV846215

Schneider Electric LV846215 MasterPact MTZ2 2500 A Circuit B

MPN LV846215
Active

Schneider Electric MasterPacT MTZ2, LV846215, 4P drawout circuit breaker, 2500 A at 40 °C, H2V 100 kA 415 V AC performance.

$11,204.46 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846215 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846215 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width556 mm
Height439 mm
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 2500 A — what this breaker delivers

The Schneider Electric LV846215 is a MasterPact MTZ2 drawout circuit breaker rated 2500 A at 40 °C, 4 poles, with H2V performance class delivering 100 kA breaking capacity at 415 V AC. It's built for main incoming or large feeder protection in power distribution — the kind of install where selectivity and fault clearance speed decide uptime. Category B selectivity means it coordinates with downstream breakers to isolate only the faulted branch, keeping the rest of the plant live. The 25 ms maximum break time and 220 kA making capacity tell you it handles high-energy faults without cascading upstream — critical for switchboard integrity. Rated insulation voltage is 1000 V AC, operational voltage 440 V AC, with impulse withstand at 12 kV. The short-time withstand rating (Icw) holds 100 kA for 1 second — enough for full-selectivity schemes with downstream breakers clearing in their own time band.

Drawout mounting and panel integration

Drawout chassis means the breaker slides out for inspection or replacement without disturbing the bus connections — a standard requirement for main breakers in industrial switchgear. Mounting support is rails or base plate; connection pitch is 115 mm. Dimensions: 556 mm wide, 439 mm high, 403 mm deep. That depth matters when you're laying out the cabinet — make sure the drawout rail has clearance for the full travel. IP30 protection is typical for indoor switchgear; no special sealing for washdown environments. Neutral position is right.

Operating altitude 0–2000 m without derating, 2000–5000 m with derating. Ambient temperature range: -25 to 70 °C operating, -40 to 85 °C storage. Power dissipation at rated current is 600 W — factor that into the switchgear ventilation calculation.

MPN