Skip to main content
Schneider Electric LV846540

Schneider Electric LV846540 MasterPact MTZ2 08 H10, 800 A, 5

MPN LV846540
Active

Schneider Electric MasterPact MTZ2, LV846540, 3P fixed circuit breaker, 800 A at 40 °C, 50 kA Icu/Ics at 1150 V AC, H10 performance level.

$10,650.49 – $11,183.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846540 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage1150 V AC 50/60 Hz
Insulation voltage ui1250 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846540 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width422 mm
Height352 mm
Electrical life cycles500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-2
Mechanical life cycles25000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

What this breaker delivers

The Schneider Electric LV846540 is a MasterPact MTZ2 08 H10 fixed circuit breaker, 3-pole, rated 800 A at 40 °C. It carries a 50 kA ultimate breaking capacity (Icu) and 50 kA service breaking capacity (Ics) at 1150 V AC 50/60 Hz — both at the same level, which means the breaker can be reclosed immediately after clearing a fault at its full rating without derating for the next operation. That matters for critical power-distribution protection where a single fault event can't force a breaker swap. Category B selectivity (per EN/IEC 60947-2) means it coordinates with downstream breakers to isolate only the faulted branch, keeping the rest of the bus live. Rated insulation voltage is 1250 V AC, impulse withstand 12 kV — headroom for 1150 V systems with transient margins.

Fixed-mount chassis, 422 mm wide × 352 mm high × 300 mm deep. Connection pitch 115 mm. Mounts on rails or a base plate — typical for switchboard or MCC integration where the breaker stays in place and doesn't get drawn out for maintenance. Rear connections both top and bottom; upside and downside are both rear, so the cable entry and exit are on the same plane. IP30 front face — protected against tools and wires >2.5 mm, but not sealed against dust ingress; install in a clean, enclosed panel.

Durability and environment

Mechanical durability: 25,000 cycles with periodic preventive maintenance. Electrical durability: 500 cycles at 1150 V AC, 50/60 Hz per EN/IEC 60947-2. Maximum breaking time 25 ms, closing response 70 ms — fast enough to limit arc energy in a fault. Altitude: full rating up to 2000 m, derated above that to 5000 m.

MPN
LV846540