Skip to main content
Schneider Electric LV847110

Schneider Electric LV847110 MasterPact MTZ1 3P 630A Circuit

MPN LV847110
Active

Schneider Electric MasterPact MTZ1, fixed circuit breaker, 3P, 630 A at 40 °C, H1 42 kA 415 V AC, push-button control, without control unit.

$2,460.13 – $2,583.12 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV847110 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch70 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV847110 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth209 mm
Width276 mm
Height301 mm
Electrical life cycles3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23 A: 3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23 A: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Mechanical life cycles12500 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV847110 is a Schneider Electric MasterPact MTZ1 fixed-mount circuit breaker, 3-pole, rated 630 A at 40 °C. That 630 A continuous current is the In — the breaker carries that load without tripping under normal conditions. The H1 performance level gives you 42 kA ultimate breaking capacity (Icu) at 415 V AC, which is the same 42 kA you get at 440 V, 500 V, and 690 V — the breaker doesn't derate its interrupting rating across the common industrial voltage range. That matters for panel coordination: if your fault current at the bus is, say, 35 kA, this breaker clears it without upstream intervention. Selectivity Category B means it's designed for full discrimination with downstream devices — a short on a branch won't take the main breaker out. The short-time withstand (Icw) is 42 kA for 1 second — that's the current it can carry for that duration while the downstream breaker clears a fault, essential for selective coordination studies.

Fixed-mount version — bolts to a base plate or rails (mounting support listed as rails and base plate). The connection pitch is 70 mm, and both upside and downside connections accept front or rear terminations. That rear-connection option is useful when you're feeding a busbar stack behind the panel and don't want cable loops in front. Fine inside a locked panel; not for outdoor or washdown locations. Altitude derating starts above 2000 m — if you're installing at 3000 m, you'll need to reduce the continuous current per the manufacturer's curve.

Also compliant with IEC 61557-12 for measuring equipment. Electrical durability: 6000 cycles at 440 V AC under AC-3 motor-switching duty, 3000 cycles at 690 V AC. Mechanical durability is 12,500 cycles with periodic preventive maintenance.

MPN
LV847110