Specifications

LV847110 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ1
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV847110 — Electrical ratings
ParameterValue
Rated current (In)630 A at 40 °C
Sensor rating400 A 630 A
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV847110 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)42 kA at 220/415 V AC 50/60 Hz 42 kA at 440 V AC 50/60 Hz 42 kA at 500/525 V AC 50/60 Hz 42 kA at 660/690 V AC 50/60 Hz
Rated service breaking capacity (Ics)42 kA at 220/415 V AC 50/60 Hz 42 kA at 440 V AC 50/60 Hz 42 kA at 500/525 V AC 50/60 Hz 42 kA at 660/690 V AC 50/60 Hz
Rated short-time withstand current (Icw)42 kA 0.5 s 42 kA 1 s 24 kA 3 s
Rated short-circuit making capacity (Icm)88 kA 220/415 V AC at 50/60 Hz 88 kA 440 V AC at 50/60 Hz 88 kA 500/525 V AC at 50/60 Hz 88 kA 660/690 V AC at 50/60 Hz
Performance typeH1 42 kA 415 V AC
LV847110 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.50 ms
Mechanical durability (cycles)12500 cycles with periodic preventive maintenance
Electrical durability (cycles)3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation30 W
LV847110 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportRails Base plate
Width276 mm
Height301 mm
Depth209 mm
Connection pitch70 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV847110 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV847110 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The LV847110 is a Schneider Electric MasterPact MTZ1 fixed-mount circuit breaker, 3-pole, rated 630 A at 40 °C. That 630 A continuous current is the In — the breaker carries that load without tripping under normal conditions. The H1 performance level gives you 42 kA ultimate breaking capacity (Icu) at 415 V AC, which is the same 42 kA you get at 440 V, 500 V, and 690 V — the breaker doesn't derate its interrupting rating across the common industrial voltage range. That matters for panel coordination: if your fault current at the bus is, say, 35 kA, this breaker clears it without upstream intervention. Selectivity Category B means it's designed for full discrimination with downstream devices — a short on a branch won't take the main breaker out. The short-time withstand (Icw) is 42 kA for 1 second — that's the current it can carry for that duration while the downstream breaker clears a fault, essential for selective coordination studies.

Fixed-mount version — bolts to a base plate or rails (mounting support listed as rails and base plate). The connection pitch is 70 mm, and both upside and downside connections accept front or rear terminations. That rear-connection option is useful when you're feeding a busbar stack behind the panel and don't want cable loops in front. Fine inside a locked panel; not for outdoor or washdown locations. Altitude derating starts above 2000 m — if you're installing at 3000 m, you'll need to reduce the continuous current per the manufacturer's curve.

Also compliant with IEC 61557-12 for measuring equipment. Electrical durability: 6000 cycles at 440 V AC under AC-3 motor-switching duty, 3000 cycles at 690 V AC. Mechanical durability is 12,500 cycles with periodic preventive maintenance.

Frequently asked questions

How do I get current pricing and availability for LV847110?

Submit an RFQ. We source this breaker to order and confirm current pricing and availability at quote time.

What is LV847110's breaking capacity at 415 V AC?

The ultimate breaking capacity (Icu) is 42 kA at 415 V AC, and the service breaking capacity (Ics) is the same 42 kA — no derating across the 220-690 V range.

What compliance documentation does this brand provide for LV847110?

The breaker is designed to EN/IEC 60947-1, EN/IEC 60947-2, and IEC 61557-12. It carries a suitability-for-isolation marking per EN/IEC 60947-2.

MPN