Skip to main content
Schneider Electric LV848060

Schneider Electric LV848060 MasterPact MTZ2 20 H1, 2000 A, 4

MPN LV848060
Active

Schneider Electric MasterPact MTZ2 20 H1, fixed circuit breaker, 4P, 2000 A at 40 °C, 66 kA breaking at 415 V AC, IP30.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848060 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV848060 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 20 H1 — 2000 A fixed breaker, Category B selectivity

The Schneider Electric LV848060 is a MasterPact MTZ2 20 H1 fixed-mount circuit breaker, 4-pole, rated 2000 A continuous at 40 °C. This is the H1 performance variant, delivering 66 kA rated service breaking capacity (Ics) at 415 V AC — the same figure holds across 440 V, 500/525 V, and 660/690 V AC, so you don't lose headroom at higher voltages. Category B selectivity (per EN/IEC 60947-2) means it's designed for full discrimination with downstream breakers, critical for minimizing outage scope in a distribution board. Rated short-time withstand (Icw) is 66 kA for 0.5 s and 1 s, dropping to 36 kA at 3 s — that 1-second window covers most delayed-tripping coordination schemes. Making capacity (Icm) hits 145 kA at 415 V, confirming the breaker can close into a full fault without contact welding. Mechanical durability is 20,000 cycles with periodic preventive maintenance; electrical endurance under AC-3 motor-switching duty is 6,000 cycles at 690 V.

Fixed-mount chassis, 352 mm high × 537 mm wide × 300 mm deep. Connection pitch is 115 mm. Upside and downside connections accept both front and rear terminations, giving flexibility for busbar or cable entry in a switchboard. Mounts on rails or a base plate — typical for a dedicated MCC or distribution section.

Also complies with IEC 61557-12 for insulation monitoring. Rated insulation voltage (Ui) 1000 V AC, rated impulse withstand (Uimp) 12 kV.

MPN
LV848060