Skip to main content
Schneider Electric LV848187

Schneider Electric LV848187 MasterPact MTZ2 32 H1, 3200 A, 4

MPN LV848187
Active

Schneider Electric MasterPact MTZ2 series, LV848187, fixed-mount power circuit breaker, 3200 A rated current, 4 poles, H1 66 kA breaking performance at 415 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848187 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV848187 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The Schneider Electric LV848187 is a MasterPact MTZ2 32 H1 fixed-mount power circuit breaker rated 3200 A at 40 °C, with 4 poles and a Category B selectivity profile.

This breaker carries an H1 performance class: 66 kA Ics at 220/415 V, 440 V, 500/525 V, and 660/690 V AC. That's the service breaking capacity — the current it can clear and still be used again without inspection. The Icw short-time withstand is also 66 kA for 0.5, 1, and 3 seconds, which gives you real headroom for selective coordination downstream. Making capacity (Icm) hits 145 kA peak at 415 V, meaning it can close into a bolted fault and survive.

Physical fit and mounting constraints

Fixed-mount design, 537 mm wide, 352 mm tall, 300 mm deep. Connection pitch is 115 mm. Mounts on rails or a base plate. Neutral sits on the right. IP30 enclosure rating — it's for switchgear cubicles, not washdown areas.

Environmental and application limits

Rated insulation voltage is 1000 V AC, operational voltage 690 V AC. Impulse withstand is 12 kV — covers the typical surge environment in industrial power systems.

Durability and power loss

Mechanical endurance is 20,000 cycles with periodic preventive maintenance. Electrical durability varies by duty: 6,000 cycles under AC-3 (motor switching) at 440/690 V, 5,000 cycles under AC-23A at 440 V. Maximum break time is 25 ms, closing response 70 ms. Power dissipation runs 420 W at rated current — factor that into your cubicle ventilation.

Standards compliance and documentation

Meets EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H (for selectivity), and IEC 61557-12 (for power metering if equipped). Control is push-button type; this variant ships without a control unit — you add the Micrologic trip unit separately.