Skip to main content
Schneider Electric LV848439

Schneider Electric LV848439 MasterPact MTZ2 3200 A Drawout C

MPN LV848439
Active

Schneider Electric MasterPact MTZ2, LV848439, drawout circuit breaker, 4P, 3200 A at 40 °C, H2 100 kA at 415 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848439 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 3200 A — the 4-pole drawout frame for high-current distribution

The Schneider Electric LV848439 is a MasterPact MTZ2 drawout circuit breaker, 4-pole, rated 3200 A at 40 °C with H2 performance class delivering 100 kA breaking capacity at 415 V AC. This is the drawout version — the breaker unit withdraws from the chassis for safe inspection and replacement without disturbing line or load connections. The chassis adds 103 mm to the depth (403 mm with chassis vs 300 mm without) and 63 mm to the width (556 mm vs 493 mm).

Breaking performance and coordination headroom

Service breaking capacity (Ics) holds 100 kA at 440 V AC, 85 kA at 690 V AC — that's full Icu at 415 V and still 85% at 690 V, giving real coordination headroom for transformer-fed switchboards where fault current can hit 85 kA for 1 second (Icw). Making capacity (Icm) is 220 kA at 415 V — the breaker must close onto a bolted fault and hold; this rating says it can. Maximum breaking time is 25 ms, closing response 70 ms, which keeps arc energy low enough for downstream component protection. Electrical durability: 6000 cycles AC-3 (motor switching) at 440/690 V, 5000 cycles at 440 V per IEC 60947-2.

Lifecycle and sourcing — current production, quoted to order

Standards compliance: EN/IEC 60947-1, EN/IEC 60947-2 (including Annex H for EMC), and IEC 61557-12 for power metering.

Integration — panel footprint and connection options

Mounting is drawout on rails or base plate. Connection pitch is 115 mm. Both front and rear connection are available for both upside and downside, giving flexibility in switchboard layout — rear connection keeps the front clean for busbar runs; front connection simplifies cable termination. IP30 protection conforming to EN 60529 — protected against tools >2.5 mm, not against water ingress. This is standard for indoor switchgear; no washdown rating. Power dissipation is 670 W at rated current — factor this into enclosure ventilation design. The breaker ships without a control unit (push-button control type); the Micrologic trip unit is ordered separately based on protection requirements.

MPN