Schneider LX1FG036 TeSys F Contactor Coil, 36 V AC 50 Hz

MPN LX1FG036
Obsolete

Schneider Electric TeSys F series, contactor coil LX1FG036, 36 V AC 50 Hz, 805 VA inrush, 55 VA hold, without built-in suppressor module.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1FG036 specifications
ParameterValue
Control circuit typeAC 50 Hz
Main product or component typeContactor coil
Coil voltage36 V AC 50 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time20...35 ms closing 7...15 ms opening
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG036 is a replacement contactor coil from the TeSys F range, designed to energize the magnetic circuit of a TeSys F contactor. It operates on 36 V AC at 50 Hz, drawing 805 VA inrush at cos φ 0.3 and 55 VA holding power under the same conditions. The coil has no built-in suppressor module, so external suppression (RC snubber or varistor) must be added across the coil terminals if the control circuit requires it — common practice on PLC-driven panels to protect solid-state outputs from inductive kickback.

Closing time is 20 to 35 ms, opening time 7 to 15 ms — fast enough for most motor-starting and switching applications, but not for precision timing circuits. The coil dissipates 18 to 24 W at 50 Hz, which adds to the enclosure's thermal load; if the contactor is in a sealed panel with other heat sources, derating or forced ventilation may be needed. Control circuit voltage limits are specified: dropout occurs between 0.35 and 0.55 Uc (12.6 to 19.8 V), and the coil picks up reliably between 0.85 and 1.1 Uc (30.6 to 39.6 V) at 55 °C. This means a 36 V AC supply must stay within that band under load — a sagging transformer secondary below 30.6 V will cause the contactor to drop out. The coil's DC resistance is 0.37 Ω at 20 °C, and closed-circuit inductance is 0.07 H.

Deployment context

The 36 V AC control voltage is typical for panels with a separate control transformer stepping down from 400 V or 480 V line power. Because the coil lacks a built-in suppressor, panel builders should plan for an external RC network or diode across the coil terminals when the contactor is driven by a PLC or solid-state relay output.