Skip to main content
Schneider Electric LX1FG036 — Contactor & Starter Coils

Schneider LX1FG036 TeSys F Contactor Coil, 36 V AC 50 Hz

MPNLX1FG036
Obsolete

Schneider Electric TeSys F series, contactor coil LX1FG036, 36 V AC 50 Hz, 805 VA inrush, 55 VA hold, without built-in suppressor module.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FG036 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module
LX1FG036 — Electrical
ParameterValue
Control circuit voltage [Uc]36 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)0.37 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)0.07 H
LX1FG036 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz
LX1FG036 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FG036 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG036 is a replacement contactor coil from the TeSys F range, designed to energize the magnetic circuit of a TeSys F contactor. It operates on 36 V AC at 50 Hz, drawing 805 VA inrush at cos φ 0.3 and 55 VA holding power under the same conditions. The coil has no built-in suppressor module, so external suppression (RC snubber or varistor) must be added across the coil terminals if the control circuit requires it — common practice on PLC-driven panels to protect solid-state outputs from inductive kickback.

Closing time is 20 to 35 ms, opening time 7 to 15 ms — fast enough for most motor-starting and switching applications, but not for precision timing circuits. The coil dissipates 18 to 24 W at 50 Hz, which adds to the enclosure's thermal load; if the contactor is in a sealed panel with other heat sources, derating or forced ventilation may be needed. Control circuit voltage limits are specified: dropout occurs between 0.35 and 0.55 Uc (12.6 to 19.8 V), and the coil picks up reliably between 0.85 and 1.1 Uc (30.6 to 39.6 V) at 55 °C. This means a 36 V AC supply must stay within that band under load — a sagging transformer secondary below 30.6 V will cause the contactor to drop out. The coil's DC resistance is 0.37 Ω at 20 °C, and closed-circuit inductance is 0.07 H.

Deployment context

The 36 V AC control voltage is typical for panels with a separate control transformer stepping down from 400 V or 480 V line power. Because the coil lacks a built-in suppressor, panel builders should plan for an external RC network or diode across the coil terminals when the contactor is driven by a PLC or solid-state relay output.

Frequently asked questions

What is the closest alternative to LX1FG036?

There is no official successor order code listed for this coil. Any replacement must be verified against the contactor frame's coil voltage, frequency, mounting, and mechanical interface. A qualified alternative would need to match the 36 V AC 50 Hz control circuit and the TeSys F mechanical fit.

What is the TeSys range?

The LX1FG036 belongs to the TeSys F range of contactors and accessories from Schneider Electric, designed for motor switching and general-purpose load control in industrial panels.

What is the category 22341-CONTACTOR,D,K,&F ACCESS?

That category code indicates this part is an accessory (coil) for TeSys D, K, and F contactor frames. It is a catalog classification, not a functional spec.

MPN