Schneider Electric LX1FG154

TeSys LX1FG154 Contactor Coil, 154 V AC 50 Hz, Obsolete

MPN LX1FG154
Obsolete

Schneider Electric TeSys F range, LX1FG154 contactor coil, 154 V AC 50 Hz, 805 VA inrush, 55 VA hold-in, 18...24 W heat dissipation.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1FG154 specifications
ParameterValue
Control circuit typeAC 50 Hz
Main product or component typeContactor coil
Coil voltage154 V AC 50 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time20...35 ms closing 7...15 ms opening
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG154 is a replacement contactor coil from the TeSys F range, wound for 154 V AC 50 Hz control circuits. It's the energizing element for a TeSys F frame contactor — when the coil pulls in, the main poles close and the auxiliary contacts switch. Rated for 805 VA inrush at 50 Hz (cos φ 0.3) dropping to 55 VA hold-in, so the coil sees a heavy initial surge that the control transformer must support without voltage sag. Heat dissipation runs 18...24 W at 50 Hz, which matters for enclosure thermal rise when multiple coils are energized in the same panel.

Closing time is 20...35 ms, opening 7...15 ms — fast enough for motor starting duty but not for high-speed synchronous switching. Mechanical durability is 10 Mcycles, so the coil itself is rarely the wear item in a standard panel (the main contacts and arc chambers go first). Maximum operating rate is 2400 cycles/hour at 55 °C; above that, the thermal rise in the coil windings accelerates insulation aging. Control voltage limits are drop-out at 0.35...0.55 Uc and operational pick-up at 0.85...1.1 Uc at 55 °C — meaning the coil drops out cleanly below about 54 V AC and reliably picks up above 131 V AC. If your control supply dips during a downstream fault, this coil may chatter or drop.

Coil construction note

This coil ships without a built-in suppressor module. The inductance of the closed circuit is 1.27 H, and average DC resistance is 8.19 Ω at 20 °C. Without an external RC snubber or varistor across the coil terminals, the inductive kick when de-energizing can couple noise into adjacent control wiring — standard practice is to fit a suppressor (e.g., TeSys LA4 or a generic RC unit) across the coil if the PLC output or relay driving it doesn't have one built in.

MPN
LX1FG154