Skip to main content
Schneider Electric LX1G3TLSEN

Schneider Electric LX1G3TLSEN Contactor Coil, 200-500V AC/DC

MPN LX1G3TLSEN
Active

Schneider Electric TeSys Giga LX1G3TLSEN contactor coil, 200-500 V AC/DC 50/60 Hz, 3-pole, built-in bidirectional peak limiting, IP20, push-in terminals.

$280.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1G3TLSEN specifications
ParameterValue
Main product or component typeContactor coil
Coil voltage200...500 V AC/DC 50/60 Hz
IP ratingIP20
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-76...176 °F (-60...80 °C)
Pollution degree3 IEC 60947-1
Mechanical life cycles5 Mcycles
Operating time20...35 ms opening 40...55 ms closing
Operating temperature-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

Coil voltage and control circuit

The LX1G3TLSEN is a TeSys Giga contactor coil rated for a control circuit voltage of 200-500 V AC/DC at 50/60 Hz, making it a direct fit for the LC1G630-800/3P standard contactor range. Built-in bidirectional peak limiting electronics suppress voltage spikes at dropout, reducing EMI and extending the life of the control circuit contacts. Inrush power is 390 W (670 VA) and hold-in power drops to 11 W (17 VA), so the control transformer sizing is driven by the inrush demand, not the steady-state draw.

Operating margins and durability

Operating time is 20-35 ms opening and 40-55 ms closing, which coordinates with the contactor's arc chamber timing for reliable switching under load. Mechanical durability is rated at 5 million cycles, and the maximum operating rate is 600 cycles per minute at 60 °C — this coil is built for high-duty-cycle applications like conveyor or pump control. Control circuit voltage limits: operational range is 0.8-1.1 Uc at 60 °C, and dropout occurs between 0-0.45 Uc — the wide dropout margin prevents nuisance dropouts during voltage sags.

Sourcing and compliance

Approvals include EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1, covering industrial control equipment for panel builds in North America and Europe. EMC immunity meets IEC 60947-4-1 with 20 V/m radiated immunity per EN/IEC 61000-4-3 and voltage dips/interruptions immunity per SEMI F47 — suitable for semiconductor fab and other sensitive environments.

MPN