Skip to main content
Schneider Electric LX1LD127

Schneider LX1LD127 TeSys coil, 127 V AC 50 Hz, obsolete

MPN LX1LD127
Active

Schneider Electric TeSys Integral replacement coil, LX1LD127, 127 V AC 50 Hz, 9.8 Ohm, 350-400 VA inrush.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1LD127 specifications
ParameterValue
Control circuit typeAC 50 Hz
Main product or component typeCoil
Coil voltage127 V AC 50 Hz

Product details

The LX1LD127 is a replacement coil for the TeSys Integral series of motor starters and contactors from Schneider Electric. It is a 127 V AC 50 Hz control coil, meaning it is designed to be energized by a 127 V AC control circuit at 50 Hz to pull in the contactor's armature. The coil draws 350 to 400 VA inrush at 50 Hz with a power factor of 0.55 to pull in, then settles to 20 to 30 VA hold-in power at 50 Hz with a power factor of 0.28. The DC resistance measures 9.8 Ohm at 68 °F (20 °C), and the inductance of the closed circuit is 2.13 H. Operational voltage range is 0.85 to 1.1 times the rated control voltage (Uc) at up to 131 °F (55 °C); dropout occurs between 0.25 and 0.7 Uc. This means the coil will hold in reliably down to about 108 V AC and will drop out somewhere between 32 and 89 V AC, depending on temperature.

MPN
LX1LD127