Schneider Electric LX4FH140

Schneider TeSys LX4FH140 Contactor Coil, 140 V DC, Active

MPN LX4FH140
Active

Schneider Electric TeSys LX4FH140, contactor coil, 140 V DC, DC wide range, without built-in suppressor module, active lifecycle.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX4FH140 specifications
ParameterValue
Control circuit typeDC wide range
Main product or component typeContactor coil
Coil voltage140 V DC
Temp operating max55 °C
Temp operating min-5 °C
Operating time40...50 ms closing 40...65 ms opening
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX4FH140 is a replacement contactor coil from the Schneider Electric TeSys range, designed for FH-series contactors. It operates on a 140 V DC control circuit, with a DC wide-range control circuit type. This is a service part — the coil itself, not a complete contactor — meant for field replacement when the original coil fails on a line. The coil's operating time is 40 to 50 ms for closing and 40 to 65 ms for opening. That timing is within the standard range for a DC-operated contactor of this class; the opening time spread reflects the lack of a built-in suppressor module, which allows the magnetic field to collapse at its natural rate.

Control voltage and coil resistance — what to verify before installation

Rated control circuit voltage is 140 V DC, with an operational range of 0.85 to 1.1 Uc at 131 °F (55 °C). That means the coil will pick up reliably between roughly 119 V DC and 154 V DC at the upper end of its ambient temperature range. Drop-out occurs between 0.15 and 0.2 Uc — so the contactor drops out between 21 V DC and 28 V DC, which gives a clean release margin below the pick-up threshold. Average coil resistance is 25.84 ohms during inrush at 68 °F (20 °C), rising to 5786 ohms in the holding state at the same temperature. That ratio — about 224:1 — is typical for a DC economized coil: the inrush current establishes the magnetic circuit, then the holding current drops to a fraction to reduce heat dissipation. The absence of a built-in suppressor module means the installer must add an external flyback diode or varistor across the coil terminals to protect the DC control circuit from the inductive kick when the contactor opens.

Deployment context — panel integration

The ambient air temperature for operation is 23 to 131 °F (-5 to 55 °C), which covers most indoor industrial panel environments. No special washdown or outdoor sealing applies — this is a standard panel component, not an IP-rated field device.

MPN
LX4FH140