Schneider Electric LX9FH0482

TeSys LX9FH0482 Contactor Coil, 48 V AC, Low Consumption

MPN LX9FH0482
Obsolete

Schneider Electric TeSys F series, LX9FH0482 specific contactor coil, 48 V AC 40...400 Hz low consumption, without built-in suppressor module.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FH0482 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption
Main product or component typeSpecific contactor coil
Coil voltage48 V AC 40...400 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time25 ms opening 45 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FH0482 is a specific replacement coil for the TeSys F contactor range, designed for 48 V AC control circuits at 40...400 Hz with low-hold-power consumption. It is not a standalone contactor — it replaces the coil assembly inside a TeSys F frame, so the BOM line should reference the parent contactor order code, not this coil alone.

Rated control voltage is 48 V AC across 40...400 Hz, with operational limits of 0.85...1.1 Uc at 131 °F (55 °C) and drop-out between 0.35...0.55 Uc. That means the coil pulls in reliably down to about 40.8 V and drops out between 16.8 and 26.4 V — important for brownout ride-through or low-voltage release logic in the panel. Opening time is 25 ms, closing time is 45 ms. For a contactor coil these are the mechanical stroke times; the actual arc extinction depends on the contactor's main poles. The coil draws 560...660 VA inrush and settles to 8...10 VA holding, so the control transformer must be sized for the inrush peak, not the steady-state figure. That rate suits frequent start-stop applications like conveyor indexing or compressor cycling, but thermal derating applies above 55 °C ambient.

Integration Notes for Panel Builders

This coil has no built-in suppressor module. For AC control circuits, an external RC snubber or varistor across the coil terminals is recommended to limit switching transients that could couple into the PLC output or adjacent electronics. The coil resistance measures 2.96 Ω inrush and 72 Ω holding at 68 °F (20 °C) — useful for verifying coil integrity with an ohmmeter before installation. Heat dissipation runs 8.4...10.4 W during holding. In a densely populated TeSys F panel, that heat adds up — ensure adequate ventilation or forced cooling if multiple coils are energized continuously in a confined enclosure.

MPN
LX9FH0482