Skip to main content
Schneider Electric LX9FH0482 — Contactor & Starter Coils

TeSys LX9FH0482 Contactor Coil, 48 V AC, Low Consumption

MPNLX9FH0482
Active

Schneider Electric TeSys F series, LX9FH0482 specific contactor coil, 48 V AC 40...400 Hz low consumption, without built-in suppressor module.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX9FH0482 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FH
Coil technologyWithout built-in suppressor module
LX9FH0482 — Electrical
ParameterValue
Control circuit voltage [Uc]48 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)2.96 Ohm inrush 68 °F (20 °C) 72 Ohm holding 68 °F (20 °C)
LX9FH0482 — Power & Thermal
ParameterValue
Inrush power (VA)560...660 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8...10 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8.4...10.4 W
LX9FH0482 — Performance & Durability
ParameterValue
Operating time25 ms opening 45 ms closing
Max. operating rate3600 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FH0482 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FH0482 is a specific replacement coil for the TeSys F contactor range, designed for 48 V AC control circuits at 40...400 Hz with low-hold-power consumption. It is not a standalone contactor — it replaces the coil assembly inside a TeSys F frame, so the BOM line should reference the parent contactor order code, not this coil alone.

Rated control voltage is 48 V AC across 40...400 Hz, with operational limits of 0.85...1.1 Uc at 131 °F (55 °C) and drop-out between 0.35...0.55 Uc. That means the coil pulls in reliably down to about 40.8 V and drops out between 16.8 and 26.4 V — important for brownout ride-through or low-voltage release logic in the panel. Opening time is 25 ms, closing time is 45 ms. For a contactor coil these are the mechanical stroke times; the actual arc extinction depends on the contactor's main poles. The coil draws 560...660 VA inrush and settles to 8...10 VA holding, so the control transformer must be sized for the inrush peak, not the steady-state figure. That rate suits frequent start-stop applications like conveyor indexing or compressor cycling, but thermal derating applies above 55 °C ambient.

Integration Notes for Panel Builders

This coil has no built-in suppressor module. For AC control circuits, an external RC snubber or varistor across the coil terminals is recommended to limit switching transients that could couple into the PLC output or adjacent electronics. The coil resistance measures 2.96 Ω inrush and 72 Ω holding at 68 °F (20 °C) — useful for verifying coil integrity with an ohmmeter before installation. Heat dissipation runs 8.4...10.4 W during holding. In a densely populated TeSys F panel, that heat adds up — ensure adequate ventilation or forced cooling if multiple coils are energized continuously in a confined enclosure.

Frequently asked questions

What is the closest alternative to LX9FH0482 in the TeSys F family?

The TeSys F coil family is voltage-specific. The LX9FH0482 is the 48 V AC low-consumption variant. A different control voltage (e.g., 24 V AC, 110 V AC, 220 V AC) requires a different LX9FH order code. There is no pin-compatible alternative at the same voltage — the coil is designed for the TeSys F frame and the voltage is fixed.

What compliance documentation is available for this coil?

The evidence does not list specific compliance certifications (RoHS, REACH, UL, IEC) for this order code. As a Schneider TeSys component, it typically carries CE marking and complies with relevant IEC/EN standards for contactor accessories, but the exact documentation set should be confirmed at time of order.

MPN
LX9FH0482