Skip to main content
Schneider Electric LX9FJ919

TeSys LX9FJ919 Contactor Coil, 50-56 VDC / 57-62 VAC, Obsole

MPN LX9FJ919
Active

Schneider Electric TeSys F series, LX9FJ919 specific contactor coil, 50-56 V DC / 57-62 V AC 40-400 Hz, 60 ms opening / 20 ms closing, obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FJ919 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Main product or component typeSpecific contactor coil
Coil voltage50...56 V DC 57...62 V AC 40...400 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time60 ms opening 20 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

It is not a general-purpose coil; it is designed to drop into the F-frame contactor's magnetic circuit and is rated for the mechanical duty cycle of that platform.

Control voltage is 50...56 V DC or 57...62 V AC 40-400 Hz. The coil holds in at 0.85 to 1.1 Uc at 55 °C and drops out between 0.3 and 0.5 Uc. Opening time is 60 ms, closing 20 ms. That asymmetry is typical for a large-frame contactor where the spring force for break is stiffer than the magnetic pull-in. The 3600 cycles/hour maximum at 70 °C means it can follow a fast-pulsing load profile, but for continuous high-rate applications like a welding gun you would want to check thermal rise against the 11.4 to 13.9 W heat dissipation. Mechanical durability is 10 Mcycles — that is the life of the coil's own plunger and return spring, not the contactor's main contacts. In a typical motor-start application cycling a few times an hour, that translates to decades of service. No built-in suppressor module means the coil's magnetic field collapses without internal damping. For a 500 VA inrush coil, that can generate a significant inductive kickback spike. If the control circuit uses a PLC output or solid-state relay, an external flyback diode (DC) or RC snubber (AC) across the coil terminals is recommended — the contactor's own aux contacts do not supply that protection.

Deployment context

The coil is a plug-in replacement accessed by removing the contactor's arc chute and magnet assembly.

MPN