TeSys LX9FK938 Contactor Coil, 440-560 V DC, Active

MPN LX9FK938
Active

TeSys F, specific contactor coil, 440...560 V DC low consumption, LX9FK938, 10 Mcycles mechanical durability, active lifecycle.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FK938 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Main product or component typeSpecific contactor coil
Coil voltage500 V DC 500 V AC 50/60 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time60 ms opening 20 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FK938 is a specific contactor coil from the TeSys F range, designed for 440...560 V DC low consumption control circuits. It is the replacement coil for TeSys F contactors, not a complete contactor assembly. Rated for control circuits at 500 V AC 50/60 Hz and 500 V DC, it operates across AC 40...400 Hz and DC low consumption control types. The coil draws an inrush power of 470 W at 68 °F (20 °C), with an average inrush resistance of 448 Ohm and a holding resistance of 3750 Ohm at the same temperature. Switching times are 60 ms opening and 20 ms closing, which defines the contactor's response in motor start/stop sequences. The coil has no built-in suppressor module, so external suppression (RC snubber or varistor) must be added if driving from a PLC output or solid-state relay to protect against voltage spikes.

Mechanical durability of 10 Mcycles means the coil itself is rated for 10 million mechanical operations before end-of-life — this is the coil's own life, not the contactor's electrical endurance under load. In high-cycle applications like conveyor sortation or press feeders, this rating ensures the coil won't fail before the contactor's main contacts need replacement. Heat dissipation of 15...18.3 W must be accounted for in panel thermal calculations. In a densely packed enclosure with multiple TeSys F contactors running continuously, this heat adds up and can reduce the ambient temperature margin. The coil is rated for ambient air operation from 23...131 °F (-5...55 °C). Maximum operating rate of 3600 cycles/hour at 158 °F (70 °C) sets the duty cycle limit. At lower ambient temperatures the rate can be higher, but this is the guaranteed maximum at the upper end of the temperature range. If your application exceeds 1 cycle per second continuously, the coil will overheat. Control circuit voltage limits are operational 0.85...1.1 Uc at 131 °F (55 °C) and drop-out 0.3...0.5 Uc at the same temperature. This means the coil will pick up reliably at 85% of nominal voltage (425 V for a 500 V coil) and will drop out when voltage falls below 50% (250 V). In weak grid conditions or long cable runs, verify the voltage at the coil terminals stays above the pick-up threshold.