Skip to main content
Schneider Electric LX9FL913

TeSys LX9FL913 Specific Contactor Coil, 27-39 V DC, Low Cons

MPN LX9FL913
Active

TeSys F, specific contactor coil, LX9FL913, 27-39 V DC low consumption, 22.8-27.8 W heat dissipation, 5 Mcycles mechanical durability.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FL913 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Main product or component typeSpecific contactor coil
Coil voltage27...39 V DC
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles5 Mcycles
Operating time60 ms opening 20 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

Part identity and fit

The LX9FL913 is a specific contactor coil from the TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It is a low-consumption DC coil with a control circuit voltage range of 27...39 V DC. The coil operates without a built-in suppressor module, so an external RC snubber or varistor may be needed across the coil terminals if the control circuit drives inductive loads that could cause voltage spikes. Opening time is 60 ms, closing time is 20 ms — fast enough for most motor switching but not for high-speed counting or precision timing applications where contactor bounce matters.

Electrical and thermal ratings

Rated for 27...39 V DC control voltage with operational limits of 0.85...1.1 Uc (23...43 V DC at 55 °C) and drop-out at 0.3...0.5 Uc (8...20 V DC at 55 °C). This means the coil will hold in reliably down to about 23 V and will drop out cleanly below about 20 V, preventing partial engagement that could weld contacts. Inrush power is 733 W at 20 °C; steady-state hold-in power is 48 W at 20 °C. Heat dissipation runs 22.8...27.8 W, so the panel must allow that thermal load — don't pack it tight against heat-sensitive components without airflow. That's a solid 5 Mcycles for a coil in this class — expect the contactor's electrical life to be the limiting factor in most motor-switching applications. The coil accepts AC control supply from 40 to 400 Hz as well as DC, giving flexibility if the control transformer is shared with other AC-powered devices.

MPN
LX9FL913