Skip to main content
Schneider Electric LX9FL913 — Contactor & Starter Coils

TeSys LX9FL913 Specific Contactor Coil, 27-39 V DC, Low Cons

MPNLX9FL913
Active

TeSys F, specific contactor coil, LX9FL913, 27-39 V DC low consumption, 22.8-27.8 W heat dissipation, 5 Mcycles mechanical durability.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FL913 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FL
Coil technologyWithout built-in suppressor module
LX9FL913 — Electrical
ParameterValue
Control circuit voltage [Uc]27...39 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
LX9FL913 — Power & Thermal
ParameterValue
Inrush power (W)733 W 68 °F (20 °C))
Hold-in power (W)48 W 68 °F (20 °C)
Heat dissipation22.8...27.8 W
LX9FL913 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate1800 cyc/h 158 °F (70 °C)
Mechanical durability5 Mcycles
LX9FL913 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Part identity and fit

The LX9FL913 is a specific contactor coil from the TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It is a low-consumption DC coil with a control circuit voltage range of 27...39 V DC. The coil operates without a built-in suppressor module, so an external RC snubber or varistor may be needed across the coil terminals if the control circuit drives inductive loads that could cause voltage spikes. Opening time is 60 ms, closing time is 20 ms — fast enough for most motor switching but not for high-speed counting or precision timing applications where contactor bounce matters.

Electrical and thermal ratings

Rated for 27...39 V DC control voltage with operational limits of 0.85...1.1 Uc (23...43 V DC at 55 °C) and drop-out at 0.3...0.5 Uc (8...20 V DC at 55 °C). This means the coil will hold in reliably down to about 23 V and will drop out cleanly below about 20 V, preventing partial engagement that could weld contacts. Inrush power is 733 W at 20 °C; steady-state hold-in power is 48 W at 20 °C. Heat dissipation runs 22.8...27.8 W, so the panel must allow that thermal load — don't pack it tight against heat-sensitive components without airflow. That's a solid 5 Mcycles for a coil in this class — expect the contactor's electrical life to be the limiting factor in most motor-switching applications. The coil accepts AC control supply from 40 to 400 Hz as well as DC, giving flexibility if the control transformer is shared with other AC-powered devices.

Frequently asked questions

What is the control voltage range for this coil?

The LX9FL913 is rated for 27...39 V DC control voltage. Operational limits are 0.85...1.1 Uc (23...43 V DC at 55 °C), and drop-out occurs at 0.3...0.5 Uc (8...20 V DC at 55 °C).

What is the heat dissipation of this coil?

Heat dissipation is 22.8...27.8 W. Inrush power is 733 W at 20 °C, and steady-state hold-in power is 48 W at 20 °C.

What is the mechanical durability of the LX9FL913?

Mechanical durability is rated at 5 million cycles, with a maximum operating rate of 1800 cycles per hour at 70 °C.

MPN
LX9FL913