Skip to main content
Schneider Electric LX9FL922

TeSys LX9FL922 specific contactor coil, 110 V AC/DC

MPN LX9FL922
Obsolete

TeSys F, specific contactor coil, LX9FL922, 110 V AC/DC control circuit, 60 ms opening / 20 ms closing, without built-in suppressor module.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FL922 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Main product or component typeSpecific contactor coil
Coil voltage110 V DC 110 V AC
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles5 Mcycles
Operating time60 ms opening 20 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

Heat dissipation runs 22.8...27.8 W — that is the continuous power the coil dumps into the panel when held in. In a densely packed TeSys F enclosure, that heat adds up; if you are grouping multiple contactors in a single cabinet, factor the dissipation into the thermal budget rather than relying on the contactor's own ventilation alone. Inrush power is 733 W at 68 °F (20 °C), which is the peak draw during the pickup transient before the coil's inductance rises. That pulse lasts only the 20 ms closing time, but it can sag a 24 V DC supply rail if the power supply is undersized for multiple simultaneous pickups. Hold-in power consumption settles to 48 W at the same temperature — the steady-state draw after the armature seals. That rate translates to one operation every two seconds, which is typical for a high-duty-cycle application like a press control or a fast-indexing conveyor — but at that rate the coil temperature will rise above the ambient, so the 158 °F limit is the coil's own internal temperature, not the cabinet ambient. The control circuit accepts AC 40...400 Hz or DC low-consumption drive. The 40 Hz lower bound means it works on 50 Hz and 60 Hz mains cleanly, and the 400 Hz upper bound covers aircraft or genset supplies. The DC low-consumption label means the coil is wound for a lower steady-state current than a standard DC coil — the 48 W hold-in confirms that — so it is compatible with electronic control outputs that cannot source a high continuous current.

The LX9FL922 is a specific contactor coil — it mounts onto the TeSys F contactor frame, not a DIN-rail base. The coil itself is the replaceable element inside the contactor assembly; swapping it changes the control voltage without replacing the entire contactor.

MPN