Skip to main content
Schneider Electric LX9FL932

LX9FL932 TeSys F Contactor Coil, 220 V DC Low Consumption

MPN LX9FL932
Active

Schneider Electric TeSys F series, specific contactor coil LX9FL932, 220 V DC low consumption, 48 W holding power, 5 Mcycles mechanical durability.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FL932 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Main product or component typeSpecific contactor coil
Coil voltage220 V DC 220 V AC
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles5 Mcycles
Operating time60 ms opening 20 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FL932 is a specific contactor coil from the Schneider Electric TeSys F range, designed to replace the coil in a TeSys F contactor when the control circuit needs 220 V AC or 220 V DC. It's a low-consumption coil — pulls 48 W holding at 20 °C, with an inrush of 733 W at the same temperature — so the thermal load on the panel stays manageable. The coil technology is without a built-in suppressor module, meaning you'll need to add an external RC snubber or varistor across the coil if the PLC output or relay driving it doesn't already have suppression.

The control circuit voltage is 220 V DC and 220 V AC, so it works on either supply — handy if your control transformer is AC but you have a DC bus elsewhere. The operational limits are 0.85 to 1.1 Uc at 55 °C, meaning the coil will pick up reliably between 187 V and 242 V; drop-out happens between 30% and 50% of Uc (66 V to 110 V), so it won't drop out on a brief sag. Heat dissipation runs 22.8 to 27.8 W, which matters for enclosure sizing — that's roughly the heat of a small soldering iron running continuously inside the panel. Mechanical durability is 5 million cycles, typical for a contactor coil of this class; the maximum operating rate is 1800 cycles per hour at 70 °C, so it's fine for frequent switching applications like conveyor cycling or compressor staging.

The coil mounts directly into the TeSys F contactor frame — it's a drop-in replacement, not a separate DIN-rail component. Opening time is 60 ms, closing time 20 ms; those are the mechanical stroke times, so factor them into your safety circuit response if the contactor is part of a guard interlock. The average resistance is 64.5 Ω inrush and 518 Ω holding at 20 °C — useful for calculating the actual current draw if you're sizing the control transformer or the DC power supply. No built-in suppressor means the coil's inductance of 3.6 H (closed circuit) will generate a flyback voltage spike on de-energization; fit a diode (for DC) or a varistor (for AC) across the coil terminals to protect the driving contact.

MPN
LX9FL932