Skip to main content
Schneider Electric LXM18MESU20N4X

Schneider Electric LXM18MESU20N4X Servo Drive, 2.0 kW

MPN LXM18MESU20N4X
Active

Schneider Electric Easy Lexium 18M servo drive, LXM18MESU20N4X, 2.0 kW at 380...440 V three-phase, 8.4 A continuous output, integrated EtherCAT, compact housing 183 x 80 x 170 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LXM18MESU20N4X specifications
ParameterValue
Main product or component typeMotion servo drive
Current5.6 A at 380...440 V, three phase
Frequency8 kHz
IP ratingIP20
Temp operating max45 °C
Temp operating min0 °C
Depth183 mm
Width80 mm
Height170 mm
Operating temperature0...45 °C

Product details

Power delivery and current capability at 8 kHz

The LXM18MESU20N4X: Rated 2.0 kW at 380...440 V with an 8 kHz switching frequency. The continuous output current is 8.4 A at that same 8 kHz; for short overloads the drive delivers 20 A for 3 seconds — enough to handle the acceleration peak of a servo motor without tripping. The 8 kHz switching frequency is the default. Running at higher carrier frequencies will reduce the continuous output current — the datasheet derating curve applies above 8 kHz. For most servo applications this is the sweet spot between motor audible noise and thermal headroom.

EtherCAT integration and panel fit

EtherCAT is integrated on the drive — no external communication module needed. The drive appears as a standard EtherCAT slave on the network; cycle times down to 31.25 µs are supported, matching the typical motion bus performance for multi-axis interpolation.

Supply and line current — sizing the feeder

Three-phase input, 380...440 V AC nominal, with supply voltage limits of 342...484 V. Line current draw is 5.6 A at rated load — size the upstream protection and wiring for this continuous draw plus the inrush of the DC bus capacitors. The drive ships without an internal EMC filter. For CE-marked installations with conducted emissions limits, an external filter is required on the input side. The filter selection depends on the cable length and the installation environment — a standard Schaffner or TDK filter for the 5.6 A line current is typical.