Schneider Electric LXM18MESU20N4X — Servo Drives

Schneider Electric LXM18MESU20N4X Servo Drive, 2.0 kW

MPNLXM18MESU20N4X
Active

Schneider Electric Easy Lexium 18M servo drive, LXM18MESU20N4X, 2.0 kW at 380...440 V three-phase, 8.4 A continuous output, integrated EtherCAT, compact housing 183 x 80 x 170 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LXM18MESU20N4X — Identification
ParameterValue
Device short nameLXM18M
Product rangeEasy Lexium 18
Product typeMotion servo drive
LXM18MESU20N4X — Electrical
ParameterValue
Rated supply voltage380...440 V (- 10...10 %) for three phase
Supply voltage limits342...484 V three phase
LXM18MESU20N4X — Environmental
ParameterValue
IP ratingIP20

Product details

Power delivery and current capability at 8 kHz

The LXM18MESU20N4X: Rated 2.0 kW at 380...440 V with an 8 kHz switching frequency. The continuous output current is 8.4 A at that same 8 kHz; for short overloads the drive delivers 20 A for 3 seconds — enough to handle the acceleration peak of a servo motor without tripping. The 8 kHz switching frequency is the default. Running at higher carrier frequencies will reduce the continuous output current — the datasheet derating curve applies above 8 kHz. For most servo applications this is the sweet spot between motor audible noise and thermal headroom.

EtherCAT integration and panel fit

EtherCAT is integrated on the drive — no external communication module needed. The drive appears as a standard EtherCAT slave on the network; cycle times down to 31.25 µs are supported, matching the typical motion bus performance for multi-axis interpolation.

Supply and line current — sizing the feeder

Three-phase input, 380...440 V AC nominal, with supply voltage limits of 342...484 V. Line current draw is 5.6 A at rated load — size the upstream protection and wiring for this continuous draw plus the inrush of the DC bus capacitors. The drive ships without an internal EMC filter. For CE-marked installations with conducted emissions limits, an external filter is required on the input side. The filter selection depends on the cable length and the installation environment — a standard Schaffner or TDK filter for the 5.6 A line current is typical.

Frequently asked questions

What is the continuous output current of LXM18MESU20N4X at 8 kHz?

8.4 A continuous at 8 kHz switching frequency. The 3-second peak is 20 A. These ratings apply at the nominal 380...440 V three-phase supply.

Does LXM18MESU20N4X include an EMC filter?

No, the drive ships without an internal EMC filter. For conducted emissions compliance in CE-marked installations, an external filter must be added on the input side.

MPN