Schneider Electric MGN19747

MGN19747 Acti9 DCP Vigi RCBO, 32 A, 30 mA, Curve B, 4P

MPN MGN19747
Obsolete

Schneider Electric Acti9 DCP Vigi RCBO, MGN19747, 32 A rated, 30 mA earth-leakage, curve B, 4P, 6 kA breaking capacity, DIN-rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN19747 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage380...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Temp operating max40 °C
Temp operating min-25 °C
ColorGrey
Depth76 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...40 °C

Product details

What this RCBO does on the panel

The MGN19747 is a 4-pole residual current breaker with overcurrent protection (RCBO) from the Acti9 DCP Vigi range, rated at 32 A with a 30 mA earth-leakage sensitivity and a B-curve magnetic trip (3–5 × In). The 6 kA breaking capacity (Icn at 380–415 V AC, 50 Hz, per EN/IEC 61009-2-1) is sized for residential and light commercial sub-distribution where fault levels stay under that threshold. The integrated earth-leakage block saves a separate RCD module and one wiring step — a space and labour win on a multi-way board.

32 A rated current (In) with thermal-magnetic trip — the thermal element handles sustained overloads, the magnetic element clears short-circuits above 3–5 × In. For a 32 A circuit, that means the RCBO will hold a 32 A continuous load and trip on a sustained overload above that, while the magnetic trip will clear a hard fault somewhere between 96 A and 160 A. The 30 mA earth-leakage sensitivity is the standard for personal protection against indirect contact in TN and TT systems. Breaking capacity of 6 kA Icn at 380–415 V AC per EN/IEC 61009-2-1, with an Icu of 6 kA per EN/IEC 60947-2. If your site study shows a higher fault level, step up to a 10 kA rated device.

Integration notes

The IP20 finger-safe front and IP40 modular enclosure mean it is suited for enclosed distribution boards only — not for wet or outdoor locations without a weatherproof cabinet. Local signalling shows ON, OFF, and fault trip via the toggle position. The contact position indicator confirms isolation status. Not padlockable, so if lockout/tagout is required, plan for a separate lockable isolator upstream.

MPN
MGN19747