Skip to main content
Schneider Electric MGN60610

MGN60610 C60H MCB, 1P C-curve 3 A, 15 kA, Multi9

MPN MGN60610
Obsolete

Schneider Electric Multi9 C60H, MGN60610, 1-pole miniature circuit breaker, C-curve, 3 A rated current, 15 kA breaking capacity at 240 V AC, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60610 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral 415 V AC 50/60 Hz phase to phase
Breaking capacity15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 24 kA Icu at 60 V DC phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60610 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The C-curve (magnetic trip at 8.5 x In +/- 20%) makes it a good fit for mixed loads with moderate inrush — think small contactor coils, control transformers, or lighting circuits where you don't want nuisance trips on startup, but you still need fast clearing on a hard short.

For a 3 A MCB feeding a control transformer in a 480 V panel stepped down to 120 V, that 15 kA gives you solid headroom against a 10 kA available fault current. The 24 kA DC rating is worth noting if you're protecting a 60 V DC bus — that's uncommon for a 1-pole MCB this size.

Snaps onto a standard 35 mm symmetrical DIN rail — 18 mm width (2 x 9 mm pitches), 81 mm tall, 73 mm deep. Fixed mounting, toggle actuation with a clear ON/OFF indicator and a separate contact position indicator so you can confirm isolation at a glance. Pollution degree 3 rated, so it's fine for the usual industrial panel environment with some conductive dust or humidity. IP20 finger-safe terminals.

MPN
MGN60610