Skip to main content
Schneider Electric MGN60610 — 1-Pole MCB (DIN Rail)

MGN60610 C60H MCB, 1P C-curve 3 A, 15 kA, Multi9

MPNMGN60610
Obsolete

Schneider Electric Multi9 C60H, MGN60610, 1-pole miniature circuit breaker, C-curve, 3 A rated current, 15 kA breaking capacity at 240 V AC, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60610 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60610 — Electrical & Protection
ParameterValue
Rated current (In)3 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral 415 V AC 50/60 Hz phase to phase
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu / AIR)15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 24 kA Icu at 60 V DC phase to phase conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60610 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60610 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60610 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The C-curve (magnetic trip at 8.5 x In +/- 20%) makes it a good fit for mixed loads with moderate inrush — think small contactor coils, control transformers, or lighting circuits where you don't want nuisance trips on startup, but you still need fast clearing on a hard short.

For a 3 A MCB feeding a control transformer in a 480 V panel stepped down to 120 V, that 15 kA gives you solid headroom against a 10 kA available fault current. The 24 kA DC rating is worth noting if you're protecting a 60 V DC bus — that's uncommon for a 1-pole MCB this size.

Snaps onto a standard 35 mm symmetrical DIN rail — 18 mm width (2 x 9 mm pitches), 81 mm tall, 73 mm deep. Fixed mounting, toggle actuation with a clear ON/OFF indicator and a separate contact position indicator so you can confirm isolation at a glance. Pollution degree 3 rated, so it's fine for the usual industrial panel environment with some conductive dust or humidity. IP20 finger-safe terminals.

Frequently asked questions

How do I get current pricing and availability for MGN60610?

The MGN60610 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is MGN60610's breaking capacity at 240 V AC?

The MGN60610 has a 15 kA Icu (ultimate breaking capacity) at 240 V AC 50/60 Hz phase-to-neutral, and a 7.5 kA Ics (service breaking capacity) at the same voltage — that's 50% of Icu, so it remains functional after clearing a fault at that level.

What compliance standards does the MGN60610 meet?

The MGN60610 is designed and tested to EN/IEC 60947-2, the standard for industrial circuit breakers. It carries pollution degree 3 rating and is suitable for isolation per that standard.

MPN
MGN60610