Schneider Electric MGN60622

MGN60622 C60H MCB, 2A C-Curve, 2P, 30kA at 240V AC

MPN MGN60622
Obsolete

Schneider Electric Multi9 C60H series, MGN60622 miniature circuit breaker, 2 A rated current, C-curve, 2-pole, 30 kA Icu at 240 V AC, 25 kA Icu at 125 V DC, thermal-magnetic trip, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60622 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60622 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60622 is a 2 A C-curve miniature circuit breaker from the Multi9 C60H series, built to EN/IEC 60947-2 for distribution duty. The C-curve magnetic trip operates at 8.5 x In ±20 % — meaning it holds through transformer inrush and moderate motor starts but trips fast on a hard short. Breaking capacity is 30 kA Icu at 240 V AC phase-to-phase and 25 kA at 125 V DC. The service breaking capacity (Ics) is 50 % of Icu at AC voltages, so after clearing a 15 kA fault at 240 V the breaker is still usable, not wrecked.

Occupies 4 x 9 mm pitches, so it takes 36 mm of rail width. Tunnel terminals accept 1 to 25 mm² rigid or flexible; strip 14 mm and torque to 2 N·m. IP20 finger-safe front means it's fine inside a closed panel but not for wet locations.