Skip to main content
Schneider Electric MGN60622 — 2-Pole MCB (DIN Rail)

MGN60622 C60H MCB, 2A C-Curve, 2P, 30kA at 240V AC

MPNMGN60622
Obsolete

Schneider Electric Multi9 C60H series, MGN60622 miniature circuit breaker, 2 A rated current, C-curve, 2-pole, 30 kA Icu at 240 V AC, 25 kA Icu at 125 V DC, thermal-magnetic trip, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60622 — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN60622 — Electrical
ParameterValue
Rated current [In]2 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
MGN60622 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu)30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN60622 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Comb busbar / distribution block compatibilityTop or bottom: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN60622 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
MGN60622 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The MGN60622 is a 2 A C-curve miniature circuit breaker from the Multi9 C60H series, built to EN/IEC 60947-2 for distribution duty. The C-curve magnetic trip operates at 8.5 x In ±20 % — meaning it holds through transformer inrush and moderate motor starts but trips fast on a hard short. Breaking capacity is 30 kA Icu at 240 V AC phase-to-phase and 25 kA at 125 V DC. The service breaking capacity (Ics) is 50 % of Icu at AC voltages, so after clearing a 15 kA fault at 240 V the breaker is still usable, not wrecked.

Occupies 4 x 9 mm pitches, so it takes 36 mm of rail width. Tunnel terminals accept 1 to 25 mm² rigid or flexible; strip 14 mm and torque to 2 N·m. IP20 finger-safe front means it's fine inside a closed panel but not for wet locations.

Frequently asked questions

What is the breaking capacity of MGN60622?

30 kA Icu at 240 V AC phase-to-phase, 15 kA at 415 V AC, 10 kA at 440 V AC, and 25 kA at 125 V DC, all conforming to EN/IEC 60947-2.

Where can I buy MGN60622 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance standards does MGN60622 meet?

It is designed and tested to EN/IEC 60947-2 for miniature circuit breakers, with pollution degree 3 and IP20 protection. The suitability for isolation is confirmed per that standard.

MPN
MGN60622