MGN60626 C60H MCB, 2P 10A Curve C, 30 kA Icu, Multi9

MPN MGN60626
Obsolete

Schneider Electric C60H Multi9 miniature circuit-breaker, MGN60626, 2-pole 10 A curve C, 30 kA Icu at 240 V AC, thermal-magnetic trip, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60626 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60626 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60626 is a C60H miniature circuit-breaker from the Multi9 range, a 2-pole (2P) unit rated 10 A at 50 °C with a C tripping curve — meaning the magnetic release operates at 8.5 x In (±20 %), so it holds through moderate inrush from motor starters or transformer banks but clears a hard short fast. The service breaking capacity Ics at that same voltage is 15 kA (50 % of Icu), so after clearing a fault at or below that level the breaker remains usable — it does not have to be replaced after every trip, provided the fault was within the Ics envelope.

The breaker snaps onto a 35 mm symmetrical DIN rail (mounting support per) and occupies 4 x 9 mm pitches, or 36 mm width — standard for a 2P MCB in the Multi9 family.

That means it is rated for industrial distribution duty with a utilisation category A (not intended for frequent switching of motor loads, but suitable for cable and equipment protection). The breaker is suitable for isolation per the standard, and the contact position indicator gives a visible confirmation that the contacts are open.