Schneider Electric MGN60626 — 2-Pole MCB (DIN Rail)

MGN60626 C60H MCB, 2P 10A Curve C, 30 kA Icu, Multi9

MPNMGN60626
Obsolete

Schneider Electric C60H Multi9 miniature circuit-breaker, MGN60626, 2-pole 10 A curve C, 30 kA Icu at 240 V AC, thermal-magnetic trip, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60626 — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN60626 — Electrical
ParameterValue
Rated current [In]10 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Network type (AC/DC)DC
MGN60626 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu)30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN60626 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Comb busbar / distribution block compatibilityTop or bottom: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN60626 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
MGN60626 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The MGN60626 is a C60H miniature circuit-breaker from the Multi9 range, a 2-pole (2P) unit rated 10 A at 50 °C with a C tripping curve — meaning the magnetic release operates at 8.5 x In (±20 %), so it holds through moderate inrush from motor starters or transformer banks but clears a hard short fast. The service breaking capacity Ics at that same voltage is 15 kA (50 % of Icu), so after clearing a fault at or below that level the breaker remains usable — it does not have to be replaced after every trip, provided the fault was within the Ics envelope.

The breaker snaps onto a 35 mm symmetrical DIN rail (mounting support per) and occupies 4 x 9 mm pitches, or 36 mm width — standard for a 2P MCB in the Multi9 family.

That means it is rated for industrial distribution duty with a utilisation category A (not intended for frequent switching of motor loads, but suitable for cable and equipment protection). The breaker is suitable for isolation per the standard, and the contact position indicator gives a visible confirmation that the contacts are open.

Frequently asked questions

What is MGN60626's rated breaking capacity?

The MGN60626 has a breaking capacity (Icu) of 30 kA at 240 V AC phase-to-phase, 15 kA at 415 V AC, 10 kA at 440 V AC, and 25 kA at 125 V DC, all conforming to EN/IEC 60947-2.

Where can I buy MGN60626 and how is it quoted?

MGN60626 is sourced to order through independent distribution channels; it is quoted against an RFQ with availability and current pricing confirmed at quote time.

What compliance documentation does MGN60626 meet?

The MGN60626 is designed to EN/IEC 60947-2, with pollution degree 3, and is suitable for isolation per that standard. For RoHS, REACH, or UL documentation, the manufacturer's compliance declarations should be consulted.

MPN
MGN60626