Skip to main content
Schneider Electric MGN60869

MGN60869 C60N MCB, 1P 20A C-Curve, 10 kA, Multi9

MPN MGN60869
Obsolete

Schneider Electric C60N Multi9 miniature circuit breaker, MGN60869, 1-pole 20 A, C-curve, 10 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60869 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral
Breaking capacity10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60869 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60869 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, rated 20 A at 50 °C per EN/IEC 60947-2. It's a 1-pole unit with a C-curve trip characteristic — magnetic tripping at 8.5 x In ±20 % — and a 10 kA Icu breaking capacity at 240 V AC phase-to-neutral. That 10 kA rating means it can safely interrupt a fault current up to 10,000 A without welding or rupturing, which covers most commercial and light industrial panelboard applications. The service breaking capacity (Ics) is 7.5 kA at 240 V AC, or 75 % of Icu, so it's rated to clear a fault and still be usable afterward.

The 18 mm width (2 x 9 mm pitches) means it takes up a single module slot in a standard distribution board. Tunnel-type terminals accept 1 to 25 mm² rigid or flexible wire; strip length is 14 mm, torque to 2 N·m. Compatible with comb busbars on top or bottom, so daisy-chaining multiple poles in a panel is straightforward.

IP20 finger-safe terminals are fine inside an enclosure; no washdown rating here.

MPN
MGN60869