Skip to main content
Schneider Electric MGN60869 — 1-Pole MCB (DIN Rail)

MGN60869 C60N MCB, 1P 20A C-Curve, 10 kA, Multi9

MPNMGN60869
Obsolete

Schneider Electric C60N Multi9 miniature circuit breaker, MGN60869, 1-pole 20 A, C-curve, 10 kA breaking capacity at 240 V AC, thermal-magnetic trip, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60869 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60N
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60869 — Electrical & Protection
ParameterValue
Rated current (In)20 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60869 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60869 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60869 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The MGN60869 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, rated 20 A at 50 °C per EN/IEC 60947-2. It's a 1-pole unit with a C-curve trip characteristic — magnetic tripping at 8.5 x In ±20 % — and a 10 kA Icu breaking capacity at 240 V AC phase-to-neutral. That 10 kA rating means it can safely interrupt a fault current up to 10,000 A without welding or rupturing, which covers most commercial and light industrial panelboard applications. The service breaking capacity (Ics) is 7.5 kA at 240 V AC, or 75 % of Icu, so it's rated to clear a fault and still be usable afterward.

The 18 mm width (2 x 9 mm pitches) means it takes up a single module slot in a standard distribution board. Tunnel-type terminals accept 1 to 25 mm² rigid or flexible wire; strip length is 14 mm, torque to 2 N·m. Compatible with comb busbars on top or bottom, so daisy-chaining multiple poles in a panel is straightforward.

IP20 finger-safe terminals are fine inside an enclosure; no washdown rating here.

Frequently asked questions

How do I get current pricing and availability for MGN60869?

Submit an RFQ for the MGN60869. Availability and current pricing are confirmed at quote time through our independent distribution network.

What is the breaking capacity of MGN60869?

The MGN60869 has a 10 kA Icu breaking capacity at 240 V AC 50/60 Hz phase-to-neutral per EN/IEC 60947-2, and 3 kA Icu at 415 V AC. The service breaking capacity Ics is 7.5 kA at 240 V AC.

What does the C-curve on MGN60869 mean?

The C-curve means the magnetic trip fires at 8.5 x In (±20 %), so at 20 A rated current, the instantaneous trip point is between about 136 A and 204 A. This suits moderate inrush loads like small motors or lighting.

What compliance documentation does MGN60869 have?

The MGN60869 is certified to EN/IEC 60947-2. It carries IP20 protection and is rated for pollution degree 3. For specific RoHS, REACH, or UL documentation, request it with your RFQ.

MPN