Skip to main content
Schneider Electric MGN61804

MGN61804 Multi9 C60H-DC MCB, 1P, 16 A, Curve B, 20 kA DC

MPN MGN61804
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit-breaker, MGN61804, 1-pole, 16 A rated current, curve B, 20 kA Icu at 110 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61804 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 110 V DC 220 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61804 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit-breaker for distribution panels

The MGN61804 is a 1-pole DC miniature circuit-breaker from the Schneider Electric Multi9 C60H-DC series, rated 16 A with a B tripping curve. The breaking capacity is 20 kA Icu at 110 V DC, 10 kA at 220 V DC, and 6 kA at 250 V DC — all per EN/IEC 60947-2. For a 220 V DC string (common in solar or battery banks), the 10 kA rating still covers most distribution-level faults. The thermal-magnetic trip unit uses a B curve with a magnetic threshold of 5.5 x In ± 20 % DC. That is a relatively low magnetic pickup — it will trip on moderate overloads faster than a C or D curve, which matters when protecting sensitive DC loads or long cable runs where fault current may be limited.

For a procurement team freezing a panel design, this part is a straight drop-in: the Multi9 C60H-DC family is a standard catalogue line, so lead times and pricing are predictable.

Integration and wiring details

Mounting is clip-on DIN rail (EN 60715). Tightening torque is 2.5 N.m. Strip length is 14 mm. The breaker is padlockable in the OFF position, which satisfies lockout/tagout requirements during panel maintenance. The ON/OFF indicator gives a visual confirmation of contact position — useful when the toggle handle is not visible through a closed door.

The MGN61804 is certified to EN/IEC 60947-2 for DC applications, pollution degree 3 (industrial environment with conductive pollution), and tropicalisation class 2 per IEC 60068-2.

MPN