Skip to main content
Schneider Electric MGN61841

MGN61841 Multi9 C60H-DC MCB, 1 A C Curve, 2P DC

MPN MGN61841
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, MGN61841, 1 A rated current, C curve, 2 poles DC, breaking capacity 20 kA at 250 V DC, clip-on DIN rail mount, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61841 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61841 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit breaker for distribution panels

The MGN61841 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker rated 1 A at 50 °C per EN/IEC 60947-2, with a C curve magnetic trip threshold of 8.5 x In ±20 % DC. It breaks up to 20 kA at 250 V DC and 10 kA at 440 V DC, making it suitable for DC distribution sub-circuits where fault currents can reach those levels. The 2-pole design isolates both conductors, and the clip-on mounting snaps onto standard DIN rail inside a panel enclosure.

Breaking capacity and selectivity in DC systems

Unlike AC-rated MCBs that derate heavily on DC, the C60H-DC is purpose-built for DC networks. At 250 V DC it delivers 20 kA Icu; at 440 V DC it still holds 10 kA. For a 500 V DC bus the rating drops to 6 kA. That spread lets an integrator coordinate downstream loads without oversizing the branch breaker — the 1 A C curve clears fast on a short circuit while the upstream device handles the full fault.

Mounting and wiring integration

Tunnel terminals accept up to 25 mm² rigid stranded or 16 mm² flexible; strip length 14 mm, torque to 2.5 N·m. The IP20 finger-safe front and IP40 modular enclosure suit enclosed panel builds. Padlockable toggle provides local lockout-tagout without removing the breaker.

MPN
MGN61841