Skip to main content
Schneider Electric MGN61841 — 2-Pole MCB (DIN Rail)

MGN61841 Multi9 C60H-DC MCB, 1 A C Curve, 2P DC

MPNMGN61841
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, MGN61841, 1 A rated current, C curve, 2 poles DC, breaking capacity 20 kA at 250 V DC, clip-on DIN rail mount, EN/IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61841 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61841 — Electrical
ParameterValue
Rated current [In]1 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61841 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61841 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61841 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61841 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit breaker for distribution panels

The MGN61841 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker rated 1 A at 50 °C per EN/IEC 60947-2, with a C curve magnetic trip threshold of 8.5 x In ±20 % DC. It breaks up to 20 kA at 250 V DC and 10 kA at 440 V DC, making it suitable for DC distribution sub-circuits where fault currents can reach those levels. The 2-pole design isolates both conductors, and the clip-on mounting snaps onto standard DIN rail inside a panel enclosure.

Breaking capacity and selectivity in DC systems

Unlike AC-rated MCBs that derate heavily on DC, the C60H-DC is purpose-built for DC networks. At 250 V DC it delivers 20 kA Icu; at 440 V DC it still holds 10 kA. For a 500 V DC bus the rating drops to 6 kA. That spread lets an integrator coordinate downstream loads without oversizing the branch breaker — the 1 A C curve clears fast on a short circuit while the upstream device handles the full fault.

Mounting and wiring integration

Tunnel terminals accept up to 25 mm² rigid stranded or 16 mm² flexible; strip length 14 mm, torque to 2.5 N·m. The IP20 finger-safe front and IP40 modular enclosure suit enclosed panel builds. Padlockable toggle provides local lockout-tagout without removing the breaker.

Frequently asked questions

What is MGN61841's breaking capacity at 250 V DC?

The MGN61841 is rated 20 kA Icu at 250 V DC per EN/IEC 60947-2.

Where can I buy MGN61841 and how is it quoted?

The MGN61841 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does MGN61841 comply with?

The MGN61841 complies with EN/IEC 60947-2 and is certified for isolation suitability per that standard.

MPN
MGN61841