Skip to main content
Schneider Electric MGN61842

Schneider MGN61842 Multi9 C60H-DC MCB, 2A C-Curve 2P DC, 20

MPN MGN61842
Obsolete

Schneider Electric Multi9 C60H-DC MGN61842, miniature circuit breaker, 2 A, C-curve, 2-pole DC, 20 kA breaking capacity at 220 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61842 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61842 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit breaker for distribution panels

The Schneider Electric MGN61842 is a Multi9 C60H-DC miniature circuit breaker rated 2 A with a C-curve trip characteristic, designed specifically for DC networks. It occupies 4 x 9 mm pitches (36 mm wide) on a DIN rail, making it a standard 2-module width part for distribution boards. The 20 kA breaking capacity at 220 V DC (Icu per EN/IEC 60947-2) means it can safely interrupt high fault currents on a 220 V DC bus without upstream cascading — critical for DC distribution in telecom, solar combiner boxes, or battery banks.

The 2 A rated current (In) at 50 °C is the continuous load the breaker carries without tripping — sized for a 2 A DC load branch, not a motor circuit. The C-curve magnetic trip fires at 8.5 x In ±20% (roughly 17 A DC), so it handles moderate inrush from capacitive or small inductive loads without nuisance trips. Thermal-magnetic trip technology means the bimetal handles overloads (time-delayed), while the solenoid handles short-circuits (instantaneous). The 2-pole construction switches both the positive and negative legs in a DC system, which is required for isolation — the breaker carries an isolation suitability mark per EN/IEC 60947-2.

The tunnel-type terminals accept up to 25 mm² rigid stranded (AWG 4) or 16 mm² flexible, with a 14 mm strip length. Tightening torque is 2.5 N.m top or bottom. The grey colour and ON/OFF indicator (green/red) are standard for the Multi9 family.

MPN
MGN61842