Schneider Electric MGN61842 — 2-Pole MCB (DIN Rail)

Schneider MGN61842 Multi9 C60H-DC MCB, 2A C-Curve 2P DC, 20

MPNMGN61842
Obsolete

Schneider Electric Multi9 C60H-DC MGN61842, miniature circuit breaker, 2 A, C-curve, 2-pole DC, 20 kA breaking capacity at 220 V DC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61842 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61842 — Electrical
ParameterValue
Rated current [In]2 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61842 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61842 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61842 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61842 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit breaker for distribution panels

The Schneider Electric MGN61842 is a Multi9 C60H-DC miniature circuit breaker rated 2 A with a C-curve trip characteristic, designed specifically for DC networks. It occupies 4 x 9 mm pitches (36 mm wide) on a DIN rail, making it a standard 2-module width part for distribution boards. The 20 kA breaking capacity at 220 V DC (Icu per EN/IEC 60947-2) means it can safely interrupt high fault currents on a 220 V DC bus without upstream cascading — critical for DC distribution in telecom, solar combiner boxes, or battery banks.

The 2 A rated current (In) at 50 °C is the continuous load the breaker carries without tripping — sized for a 2 A DC load branch, not a motor circuit. The C-curve magnetic trip fires at 8.5 x In ±20% (roughly 17 A DC), so it handles moderate inrush from capacitive or small inductive loads without nuisance trips. Thermal-magnetic trip technology means the bimetal handles overloads (time-delayed), while the solenoid handles short-circuits (instantaneous). The 2-pole construction switches both the positive and negative legs in a DC system, which is required for isolation — the breaker carries an isolation suitability mark per EN/IEC 60947-2.

The tunnel-type terminals accept up to 25 mm² rigid stranded (AWG 4) or 16 mm² flexible, with a 14 mm strip length. Tightening torque is 2.5 N.m top or bottom. The grey colour and ON/OFF indicator (green/red) are standard for the Multi9 family.

Frequently asked questions

How do I get current pricing and availability for MGN61842?

Submit an RFQ through this listing. We source the MGN61842 through independent distribution channels and confirm availability and current pricing at quote time — no automated stock figures here.

What is MGN61842's breaking capacity at different DC voltages?

The MGN61842 delivers 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2. Match the available fault current at your system voltage before specifying.

What compliance documentation does Schneider provide for MGN61842?

The MGN61842 is certified to EN/IEC 60947-2 and carries tropicalisation treatment per IEC 60068-2. Standard compliance documentation (declaration of conformity, CE mark) is available from Schneider Electric's documentation portal.

MPN