Skip to main content
Schneider Electric MGN61846

Schneider Electric MGN61846 Multi9 C60H-DC MCB, 6A 2P C-Curv

MPN MGN61846
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61846, miniature circuit breaker, 2P, 6 A, C-curve, 20 kA at 250 V DC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61846 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61846 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric MGN61846 is a Multi9 C60H-DC miniature circuit breaker — a 2-pole, 6 A thermal-magnetic unit with a C-curve trip characteristic, purpose-built for DC distribution circuits. Rated breaking capacity reaches 20 kA Icu at 250 V DC and 10 kA Icu at 440 V DC per EN/IEC 60947-2, which means it can safely interrupt high-energy DC faults without cascading upstream — critical for battery banks, UPS outputs, and solar combiner boxes where DC arc extinction is harder than AC. The magnetic trip threshold is fixed at 8.5 x In ±20% DC, so it rides through motor inrush and capacitive charging currents on DC bus lines without nuisance tripping.

DC-rated interrupting performance

Unlike a standard AC MCB, the C60H-DC is rated for DC interruption across multiple voltage points: 20 kA at 220/250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC. The 500 V DC insulation voltage (Ui) confirms the internal clearance and creepage are designed for series-stacked battery strings up to that potential.

Panel integration

Tunnel-type terminals accept up to 25 mm² rigid stranded or 16 mm² flexible — strip 14 mm, torque to 2.5 N·m. Pollution degree 3 per EN 60947-2 and tropicalisation class 2 per IEC 60068-2 mean the breaker is rated for conductive environments (condensation, occasional dust) and high-humidity storage up to 95% RH at 55 °C — typical for unheated electrical rooms in tropical climates.

MPN