Skip to main content
Schneider Electric MGN61846 — 2-Pole MCB (DIN Rail)

Schneider Electric MGN61846 Multi9 C60H-DC MCB, 6A 2P C-Curv

MPNMGN61846
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61846, miniature circuit breaker, 2P, 6 A, C-curve, 20 kA at 250 V DC, clip-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61846 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61846 — Electrical
ParameterValue
Rated current [In]6 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61846 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61846 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61846 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61846 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The Schneider Electric MGN61846 is a Multi9 C60H-DC miniature circuit breaker — a 2-pole, 6 A thermal-magnetic unit with a C-curve trip characteristic, purpose-built for DC distribution circuits. Rated breaking capacity reaches 20 kA Icu at 250 V DC and 10 kA Icu at 440 V DC per EN/IEC 60947-2, which means it can safely interrupt high-energy DC faults without cascading upstream — critical for battery banks, UPS outputs, and solar combiner boxes where DC arc extinction is harder than AC. The magnetic trip threshold is fixed at 8.5 x In ±20% DC, so it rides through motor inrush and capacitive charging currents on DC bus lines without nuisance tripping.

DC-rated interrupting performance

Unlike a standard AC MCB, the C60H-DC is rated for DC interruption across multiple voltage points: 20 kA at 220/250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC. The 500 V DC insulation voltage (Ui) confirms the internal clearance and creepage are designed for series-stacked battery strings up to that potential.

Panel integration

Tunnel-type terminals accept up to 25 mm² rigid stranded or 16 mm² flexible — strip 14 mm, torque to 2.5 N·m. Pollution degree 3 per EN 60947-2 and tropicalisation class 2 per IEC 60068-2 mean the breaker is rated for conductive environments (condensation, occasional dust) and high-humidity storage up to 95% RH at 55 °C — typical for unheated electrical rooms in tropical climates.

Frequently asked questions

What is the breaking capacity of MGN61846 at different DC voltages?

The MGN61846 provides 20 kA Icu at 220/250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2.

What compliance standards does MGN61846 meet?

The MGN61846 is designed and certified to EN/IEC 60947-2 for miniature circuit breakers, with pollution degree 3 and tropicalisation class 2 per IEC 60068-2.

MPN