MGN61852 Multi9 C60H-DC MCB 25A C-curve 2P DC, 20 kA

MPN MGN61852
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, order code MGN61852, 2-pole DC, 25 A rated current, C-curve, breaking capacity 20 kA at 250 V DC, clip-on DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61852 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61852 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit breaker, 25 A C-curve, 2 poles

The MGN61852 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker — a 2-pole, 25 A thermal-magnetic unit with a C-curve trip characteristic, built specifically for DC circuits. Rated 25 A at 50 °C per EN/IEC 60947-2, so the 25 A mark is the continuous current at elevated panel temperature — no derating guesswork needed if your enclosure stays under that ambient. Breaking capacity is the headline here: 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC. For a 250 V DC bus — common in telecom, UPS, or solar combiner panels — the full 20 kA SCCR is available. At 500 V DC the 6 kA rating still covers most industrial control circuits. The IP20 finger-safe front and IP40 inside the modular enclosure are standard for panelboard use — not rated for washdown, but fine inside a sealed cabinet. Padlockable toggle for lockout/tagout, with ON/OFF indication visible through the enclosure door.

Unlike AC breakers that rely on a zero-crossing to extinguish the arc, DC breakers must stretch and cool the arc without a natural current zero. The C60H-DC's arc chamber and contact materials are designed for that — the 20 kA Icu at 250 V DC is a real DC rating, not an AC-to-DC conversion. For a 48 V or 125 V DC control bus this breaker is oversized in voltage, which is fine; for a 500 V DC drive bus, the 6 kA breaking capacity is the limit to respect. Insulation voltage rated 500 V DC (Ui), so the internal creepage distances hold up at that level. The tunnel terminals accept up to three 1 mm² flexible conductors per pole for daisy-chaining, or a single 25 mm² for the main feed. Tightening torque 2.5 N·m top and bottom. Wire strip length 14 mm — standard for this terminal family.

MPN