Skip to main content
Schneider Electric MGN61852 — 2-Pole MCB (DIN Rail)

MGN61852 Multi9 C60H-DC MCB 25A C-curve 2P DC, 20 kA

MPNMGN61852
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, order code MGN61852, 2-pole DC, 25 A rated current, C-curve, breaking capacity 20 kA at 250 V DC, clip-on DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61852 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61852 — Electrical
ParameterValue
Rated current [In]25 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61852 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61852 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61852 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61852 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit breaker, 25 A C-curve, 2 poles

The MGN61852 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker — a 2-pole, 25 A thermal-magnetic unit with a C-curve trip characteristic, built specifically for DC circuits. Rated 25 A at 50 °C per EN/IEC 60947-2, so the 25 A mark is the continuous current at elevated panel temperature — no derating guesswork needed if your enclosure stays under that ambient. Breaking capacity is the headline here: 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC. For a 250 V DC bus — common in telecom, UPS, or solar combiner panels — the full 20 kA SCCR is available. At 500 V DC the 6 kA rating still covers most industrial control circuits. The IP20 finger-safe front and IP40 inside the modular enclosure are standard for panelboard use — not rated for washdown, but fine inside a sealed cabinet. Padlockable toggle for lockout/tagout, with ON/OFF indication visible through the enclosure door.

Unlike AC breakers that rely on a zero-crossing to extinguish the arc, DC breakers must stretch and cool the arc without a natural current zero. The C60H-DC's arc chamber and contact materials are designed for that — the 20 kA Icu at 250 V DC is a real DC rating, not an AC-to-DC conversion. For a 48 V or 125 V DC control bus this breaker is oversized in voltage, which is fine; for a 500 V DC drive bus, the 6 kA breaking capacity is the limit to respect. Insulation voltage rated 500 V DC (Ui), so the internal creepage distances hold up at that level. The tunnel terminals accept up to three 1 mm² flexible conductors per pole for daisy-chaining, or a single 25 mm² for the main feed. Tightening torque 2.5 N·m top and bottom. Wire strip length 14 mm — standard for this terminal family.

Frequently asked questions

What is the breaking capacity of MGN61852 at 250 V DC?

20 kA Icu at 250 V DC per EN/IEC 60947-2. At 440 V DC it drops to 10 kA, and at 500 V DC to 6 kA.

Where can I buy MGN61852 and get a price?

Sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What standards does MGN61852 comply with?

Designed and tested to EN/IEC 60947-2. Tropicalisation class 2 per IEC 60068-2. Pollution degree 3 per EN 60947-2.

What is the difference between C60H-DC and a standard AC MCB?

The C60H-DC is built for DC circuits with an arc chamber designed to extinguish a DC arc that has no zero-crossing. AC-only breakers cannot safely interrupt DC faults at the same voltage — this breaker's DC-specific ratings (20 kA at 250 V DC, etc.) are the key difference.

MPN
MGN61852