MGN61855 Multi9 C60H-DC DC Miniature Circuit Breaker, 40 A,

MPN MGN61855
Obsolete

Schneider Electric Multi9 C60H-DC, DC miniature circuit breaker, 2 poles, 40 A, C curve, breaking capacity 20 kA at 220 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61855 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61855 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit breaker for distribution panels

It is a 2-pole thermal-magnetic breaker rated at 40 A at 50 °C (EN/IEC 60947-2), with a C curve that trips magnetically at 8.5 x In ±20% DC. The breaking capacity reaches 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC — covering most common DC distribution voltages in industrial control panels and telecom plants. The grey modular enclosure carries IP20 (terminals) and IP40 (enclosure) protection, suitable for clean indoor panel environments.

The C curve (8.5 x In magnetic trip) means the breaker holds through moderate inrush — typical for DC motor starters, solenoid banks, or capacitive loads — but clears fast on hard shorts. At 440 V DC the interrupting rating drops to 10 kA, and at 500 V DC to 6 kA — so on a 500 V DC system, the available fault current must be verified not to exceed 6 kA. Rated insulation voltage (Ui) is 500 V DC, and the breaker is certified for isolation (suitability for isolation: Yes per EN/IEC 60947-2). That means it can be used as a disconnecting means in a DC circuit, provided the system voltage does not exceed 500 V DC.