MGN61855 Multi9 C60H-DC DC Miniature Circuit Breaker, 40 A,

MPNMGN61855
Obsolete

Schneider Electric Multi9 C60H-DC, DC miniature circuit breaker, 2 poles, 40 A, C curve, breaking capacity 20 kA at 220 V DC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61855 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61855 — Electrical
ParameterValue
Rated current [In]40 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61855 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61855 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...35 mm² (AWG 18...AWG 2) - rigid stranded Tunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - flexible Tunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 4 mm² (AWG 6) - flexible stranded
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61855 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61855 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit breaker for distribution panels

It is a 2-pole thermal-magnetic breaker rated at 40 A at 50 °C (EN/IEC 60947-2), with a C curve that trips magnetically at 8.5 x In ±20% DC. The breaking capacity reaches 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC — covering most common DC distribution voltages in industrial control panels and telecom plants. The grey modular enclosure carries IP20 (terminals) and IP40 (enclosure) protection, suitable for clean indoor panel environments.

The C curve (8.5 x In magnetic trip) means the breaker holds through moderate inrush — typical for DC motor starters, solenoid banks, or capacitive loads — but clears fast on hard shorts. At 440 V DC the interrupting rating drops to 10 kA, and at 500 V DC to 6 kA — so on a 500 V DC system, the available fault current must be verified not to exceed 6 kA. Rated insulation voltage (Ui) is 500 V DC, and the breaker is certified for isolation (suitability for isolation: Yes per EN/IEC 60947-2). That means it can be used as a disconnecting means in a DC circuit, provided the system voltage does not exceed 500 V DC.

Frequently asked questions

What is the breaking capacity of MGN61855 at 220 V DC?

The MGN61855 has a breaking capacity of 20 kA Icu at 220 V DC (conforming to EN/IEC 60947-2).

What compliance documentation does this brand provide for MGN61855?

The MGN61855 is certified to EN/IEC 60947-2, includes tropicalisation per IEC 60068-2 (class 2), and carries IP20/IP40 protection per IEC 60529. Pollution degree 3 per EN 60947-2 is specified.