Skip to main content
Schneider Electric MGN61857

MGN61857 Multi9 C60H-DC MCB, 2P, 63 A, Curve C, DC

MPN MGN61857
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit-breaker, MGN61857, 2-pole, 63 A rated current, C-curve, 20 kA breaking capacity at 250 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61857 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61857 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric MGN61857 is a 2-pole DC miniature circuit-breaker from the Multi9 C60H-DC series, rated 63 A at 50 °C with a C-curve trip characteristic. It is designed for DC distribution networks and clips onto a DIN rail for panel integration. The breaking capacity reaches 20 kA Icu at 250 V DC, dropping to 10 kA at 440 V DC and 6 kA at 500 V DC, per EN/IEC 60947-2. This makes it suitable for protecting DC bus lines, battery banks, and DC motor circuits where high interrupting capability is required.

DC Ratings and Breaking Capacity

The rated operational voltage spans 220 V, 250 V, 440 V, and 500 V DC, with the rated insulation voltage at 500 V DC. The magnetic tripping limit is set at 8.5 x In ±20% DC, so a 63 A breaker trips instantaneously on a DC fault of roughly 536 A or more.

The breaker occupies 4 x 9 mm pitches (36 mm width) on a DIN rail, with a depth of 73 mm and height of 81 mm. Clip-on mounting allows tool-less installation; the toggle handle provides local ON/OFF indication and a contact position indicator confirms the state. The tunnel-type terminals accept 1 to 35 mm² rigid stranded (AWG 18 to AWG 2) on top or bottom, with a tightening torque of 3.5 N.m.

MPN
MGN61857