Skip to main content
Schneider Electric MGN61857 — 2-Pole MCB (DIN Rail)

MGN61857 Multi9 C60H-DC MCB, 2P, 63 A, Curve C, DC

MPNMGN61857
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit-breaker, MGN61857, 2-pole, 63 A rated current, C-curve, 20 kA breaking capacity at 250 V DC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61857 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61857 — Electrical
ParameterValue
Rated current [In]63 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61857 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61857 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...35 mm² (AWG 18...AWG 2) - rigid stranded Tunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - flexible Tunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 4 mm² (AWG 6) - flexible stranded
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61857 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61857 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The Schneider Electric MGN61857 is a 2-pole DC miniature circuit-breaker from the Multi9 C60H-DC series, rated 63 A at 50 °C with a C-curve trip characteristic. It is designed for DC distribution networks and clips onto a DIN rail for panel integration. The breaking capacity reaches 20 kA Icu at 250 V DC, dropping to 10 kA at 440 V DC and 6 kA at 500 V DC, per EN/IEC 60947-2. This makes it suitable for protecting DC bus lines, battery banks, and DC motor circuits where high interrupting capability is required.

DC Ratings and Breaking Capacity

The rated operational voltage spans 220 V, 250 V, 440 V, and 500 V DC, with the rated insulation voltage at 500 V DC. The magnetic tripping limit is set at 8.5 x In ±20% DC, so a 63 A breaker trips instantaneously on a DC fault of roughly 536 A or more.

The breaker occupies 4 x 9 mm pitches (36 mm width) on a DIN rail, with a depth of 73 mm and height of 81 mm. Clip-on mounting allows tool-less installation; the toggle handle provides local ON/OFF indication and a contact position indicator confirms the state. The tunnel-type terminals accept 1 to 35 mm² rigid stranded (AWG 18 to AWG 2) on top or bottom, with a tightening torque of 3.5 N.m.

Frequently asked questions

What is the breaking capacity of MGN61857 at 250 V DC?

The breaking capacity is 20 kA Icu at 250 V DC per EN/IEC 60947-2. At 440 V DC it drops to 10 kA, and at 500 V DC to 6 kA.

What wire sizes does the MGN61857 terminal accept?

The tunnel-type terminals accept 1 to 35 mm² rigid stranded (AWG 18 to AWG 2) on top or bottom. For flexible wire with ferrule, the range is 1 to 25 mm².

Where can I buy MGN61857 and what is the sourcing process?

The MGN61857 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
MGN61857