Skip to main content
Schneider Electric MGN61867

MGN61867 Multi9 C60H-DC MCB, 1P, 16 A, K-curve, DC

MPN MGN61867
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, 1-pole, 16 A, K-curve, breaking capacity 20 kA at 110 V DC, 10 kA at 220 V DC, 6 kA at 250 V DC, clip-on DIN rail mount, grey.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61867 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 110 V DC 220 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61867 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit breaker for distribution

The MGN61867 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker, single-pole, rated 16 A at 50 °C per EN/IEC 60947-2. It is a thermal-magnetic trip unit with a K-curve — magnetic tripping at 12 x In ±20 % DC — designed for DC network protection in distribution applications. Breaking capacity is 20 kA Icu at 110 V DC, 10 kA Icu at 220 V DC, and 6 kA Icu at 250 V DC, all conforming to EN/IEC 60947-2. The rated insulation voltage (Ui) is 500 V DC, and the rated operational voltage (Ue) covers 110 V DC, 220 V DC, and 250 V DC. The K-curve means the breaker holds through moderate inrush (typical of DC motor or solenoid loads) and trips sharply on hard shorts — a fit for DC distribution where the load has a defined surge profile, not for pure resistive or long-cable runs where a B- or C-curve would be more appropriate.

Clip-on mounting to DIN rail, 18 mm width (2 x 9 mm pitches), 81 mm height, 73 mm depth. IP20 finger-safe front, IP40 inside the modular enclosure. Tightening torque 2.5 N·m. Padlockable toggle with ON/OFF indication and contact position indicator. Pollution degree 3, tropicalisation class 2 per IEC 60068-2, relative humidity 95 % at 55 °C.

MPN
MGN61867